Herunterladen Inhalt Inhalt Diese Seite drucken

Menu - clage Zip HydroTap G5 CS 100 Gebrauchs- Und Montageanleitung

Vorschau ausblenden Andere Handbücher für Zip HydroTap G5 CS 100:
Inhaltsverzeichnis

Werbung

5. Use
Blue light (Arc / Classic Plus / Classic)
• On all the time: temperature of chilled water is at the set temperature.
• Flashing: the water has not yet been chilled to the set temperature.
White light (Arc / Classic Plus)
• On all the time: temperature of sparkling water is at the set temperature.
• Flashing: the water has not yet been chilled to the set temperature.
White filter LED (Classic)
• Flashing: the filter needs to be replaced. This LED starts flashing according to filter
use and the filter capacity set in the menu.
Note: For the taps Arc and Celsius Arc the need for a filter replacement is indi-
cated by cyclically flashing all the LEDs in all three colours

Menu

The undersink unit has a touch screen which can be used to set and read the operating
parameters. By tapping on the three dashes in the top left-hand corner, you can access
the main menu. The following settings can be carried out in the menu:
'General Settings'
Language – Select the language used in the menu.
Date & Time – Set the current date and time.
'System Settings'
The steps that are necessary when using the unit for the first time can be viewed again
for maintenance purposes.
Filter Settings – Filter Flush, Filter Reset, Filter Life
Filter Flush: place the end of the hose located at the filter in a collecting container and
open the isolating valve on the hose before starting to flush the filter.
Filter Reset: resets the filter consumption data.
Temperature Setting – Set the water temperatures.
CO
Settings – CO
Flush, Reset CO
2
2
CO
Flush: Air and water inside the carbonizer are flushed out with carbon dioxide to
2
ensure that the carbonizer operates correctly.
Reset CO
: Resets the consumption data for CO
2
CO
Life: Enter the CO
lifetime.
2
2
Dispense Time – Setting the tap duration when using the filling function.
Light sensor – The light sensor on the Classic tap can be calibrated for the light
conditions at the installation location. This is necessary to ensure that the Sleep mode
energy-saving function operates correctly. Shield the tap from direct sunlight during
calibration.
Quiet Mode – The fan speed may be adjusted for quieter operation only if the
environmental temperatures are considerably lower than 35 °C.
Reset – Deactivates the password function.
'Safety & Security'
Password – A user password can optionally be set to lock the 'Settings' menu and pre-
31
, CO
Life
2
2
.
2
CLAGE
EN

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis