Lock trigger gun
This lock locks the lever of the trigger gun and
prevents the inadvertent start of the appli-
ance.
Overflow valve with pressure switch
The overflow valve prevents the permissible
working pressure from being exceeded.
If the lever on the trigger gun is released the
pressure switch turns off the pump, the high-
pressure jet ist stopped. If the lever is pulled
the pump is turned on again.

Operation

Description of the Appliance
When unpacking the product, make sure that
no accessories are missing and that none of
the package contents have been damaged. If
you detect any transport damages please
contact your dealer.
Illustrations on Page 2
1
High pressure connection
2
Water connection
3
Coupling element for water connection
4
Transport handle
5
Storage for high-pressure hose
6
Storage for mains connection cable
7
Storage for accessories
8
Mains cable with mains plug
9
Appliance switch "0/OFF"/ „I/ON"
10 Suction hose for detergent
11 Trigger gun
12 Lock trigger gun
13 High pressure hose
14 Washing brush
15 Spray lance with pressure regulation
(Vario Power)
Special accessories
Special accessories expand the possibilities
of using your appliance. Please contact your
KÄRCHER dealer for further information.
Before Startup
Illustration
Mount loose parts delivered with appliance
prior to start-up.
Illustration
Push the high pressure hose into the trig-
ger gun until it locks audibly.
Note: Make sure the connection nipple is
aligned correctly.
Check the secure connection by pulling
on the high-pressure hose.
Water supply
According to the applicable regula-
tions, the appliance must never be
used on the drinking water supply
without a system separator. Use a
suitable system separator manufactured by
KÄRCHER; or, as an alternative, a system
separator as per EN 12729 Type BA. Water
flowing through a system separator is consid-
ered non-drinkable.
Note: Impurities in the water can damage the
high-pressure pump and accessories. For
protection, the use of the KÄRCHER water fil-
ter (optional accessory, order no. 4.730-059)
is recommended.
Water supply from mains
Observe regulations of water supplier.
For connection values, see type plate/techni-
cal data.
Use a fibre-reinforced water hose (not in-
cluded) with a standard coupling. (Mini-
mum diameter 1/2 inch (13 mm),
minimum length 7.5 m).
Illustration
Screw the coupling unit (supplied) to the
water connection on the appliance.
Push the water supply hose onto the cou-
pling unit, then connect it to the water sup-
ply.
Drawing in water from open reservoirs
This high-pressure cleaner is suited to work
with the KÄRCHER suction hose with back-
flow valve (Optional accessory, order no.
4.440-238) to draw in surface water, e.g. from
water butts or ponds (see specifications for
max. suction height).
Fill the KÄRCHER suction hose with
backflow valve with water, screw to water
supply and hang into he water butt.
Separate the high pressure hose from the
high pressure connection of the appli-
ance.
Switch the appliance on (I/ON) for a max.
of 2 minutes and wait until the water exits
English 11
5
Deutsch

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis