Herunterladen Inhalt Inhalt Diese Seite drucken

Ac Voltage (Automatic Range Selection); Resistance Measurement; Acoustic Continuity Test; Diode Test - TESTBOY TV 217 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Information about the measurement

AC voltage (automatic range selection)

Measurement range
4 V
40 V
400 V
600 V
Input impedance: 10 M
Frequency response: 40 Hz - 1 kHz
Maximum input voltage: 600 V DC or 600 V AC RMS.

Resistance measurement

Measurement range
400 
4 k
40 k
400 k
4 M
40 M
Off-load voltage: 1.0 V
Overload protection: 600 V DC or 600 V AC RMS

Acoustic continuity test

Measurement range
Buzzer
Overload protection: 600 V DC or 600 V AC RMS

Diode test

Measurement range
Diode
Supply current: ~1 mA DC
Supply voltage: ~3.2 V DC
Overload protection: 600 V DC or 600 V AC RMS
26
Resolution
0.001 V
0.01 V
0.1 V
1 V
Resolution
0.1 
0.001 k
0.01 k
0.1 k
0.001 M
0.1 M
Resolution
0.1 
Resolution
0.001 V
Tolerance
± (1 % + 3 digits)
Tolerance
± (0.8 % + 3 digits)
± (1.0 % + 3 digits)
Function
The installed signal
generator sounds up to
40 Ohm
Function
The diode supply voltage is
displayed
Testboy
®
TV 217

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis