Herunterladen Inhalt Inhalt Diese Seite drucken

hanseatic HVBA8008SKC Gebrauchsanleitung Seite 57

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Problem
Possible cause
Appliance
Overheat protection
switches
triggered.
itself off.
Suction channel is
blocked.
Setting for the suction
force set too low.
Dust bag is not
Suction
positioned correctly.
force is
weak.
Dust bag is full.
Brush / nozzle is not
positioned correctly.
Filters are inserted
incorrectly or are
contaminated.
Air by-pass vent is
open.
Dust is
Filters are inserted
escaping
incorrectly or are
from the
defective.
appliance.
In rare cases this can make a whistling noise initially. This is not a
malfunction and stops after a while.
Troubleshooting table Page EN-27
Solutions, tips
Pull the mains plug out of the
socket. Clean the dirty motor
protection filter or replace it with
a new one. Clear blockages in
nozzles, telescopic tube or the
suction hose. Let the appliance
cool down for at least half an hour
before switching it on again.
Switch off the appliance and
pull out the mains plug from
the socket. Clear blockages in
nozzles, telescopic tube or the
suction hose.
Rotate the suction force control
unit (4) towards "max".
Insert the dust bag correctly.
Change the dust bag.
Position the brush / nozzle
correctly.
Insert the filter correctly or clean/
replace it with a new one.
Close the air by-pass vent.
Insert the filter correctly or
replace it with a new one.

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

20294662

Inhaltsverzeichnis