Speed during active cooling: Here, you set the speed the
brine pump will have during active cooling.
Delta-T cooling: Here, you set whether the brine pump is to
be regulated with fixed delta during cooling operation.
Speed in wait mode, cooling: Here, you set the speed the
brine pump will have in standby mode. Standby mode occurs
when active cooling is permitted but there is no need for
compressor operation.
MENU 7.1.7 - COOLING
This menu contains sub-menus where you can make ad-
vanced settings for cooling operation.
MENU 7.1.10.2 - AUTO MODE SETTING
Start cooling
Setting range: 15 – 40 °C
Stop heating
Setting range: -20 – 40 °C
Stop additional heat
Setting range: -25 – 40 °C
Filtering time
Setting range: 0 – 48 h
Time betw. cooling and heating
Setting range: 0 – 48 h
Cooling/heat sensor
Setting range: None, BT74, Zone 1 - x
Set point value cool/heat sensor
Setting range: 5 – 40 °C
Heating at subnormal room temp
Setting range: 0.5 – 10.0 °C
Cooling at excess room temp
Setting range: 0.5 – 10.0 °C
Auto: When the operating mode is set to "Auto", the installa-
tion selects when start and stop of additional heat and
cooling/heat production are permitted, depending on the
average outdoor temperature.
Stop heating, Stop additional heat: In this menu, you set the
temperatures that the system will use for control in auto
mode.
Caution
In systems where heating and cooling share the
same pipes "Stop heating" cannot be set higher
than "Start cooling" if there is not a cooling/heat-
ing sensor.
Filtering time: You can set the time over which the average
outdoor temperature is calculated. If you select 0, the cur-
rent outdoor temperature is used.
Time betw. cooling and heating: Here, you set how long the
installation will wait before it returns to heating operation
when the cooling demand has ceased or vice versa.
HPAC S40 | GB
Cooling/heat sensor
Here, you select the sensor that will be used for cooling/heat-
ing. If BT74 is installed, it will be preselected and no other
option is possible.
Set point value cool/heat sensor: Here, you can set the in-
door temperature at which the installation will change
between heating and cooling operation.
Heating at subnormal room temp: Here, you can set how
much the room temperature can drop below the desired
temperature before the installation switches to heating op-
eration.
Cooling at excess room temp: Here, you can set how much
the room temperature can increase above the desired tem-
perature before the installation switches to cooling opera-
tion.
MENU 7.1.10.3 - DEGREE MINUTES SETTING
Cooling, auto
Setting option: on/off
Start passive cooling
Setting alternative: 10 – 500 DM
Start active cooling
Setting alternative: 10 – 300 DM
DM = degree minutes
Degree minutes are a measurement of the current heat-
ing/cooling demand in the house and determine when the
compressor or additional heat will start/stop.
MENU 7.5.3 - FORCED CONTROL
Here you can force control the various components in the
installation. The most important safety functions remain
active however.
NOTE
Forced control is only intended to be used for
troubleshooting purposes. Using the function in
any other way may cause damage to the compon-
ents in your installation.