If the room temperature is constantly too low/high,
you increase/decrease the value by one step in
menu 1.1.1.
If the room temperature changes when the out-
door temperature changes, you increase/decrease
the curve slope by one step in menu 1.30.1.
Wait 24 hours before making a new setting, so that
the room temperature has time to stabilise.
MENU 1.3 - ROOM SENSOR SETTINGS
Here, you select the zone to which a sensor will belong. It is
possible to connect multiple room sensors to each zone.
Each room sensor can be given a unique name.
The control of heating and cooling is activated by ticking
the relevant option. Which options are shown depends on
which type of sensor is installed. If control is not activated,
the sensor will be the displaying sensor.
Caution
A slow heating system such as underfloor heating
may be inappropriate for controlling with room
sensors.
MENU 1.30.7 - OWN CURVE
Own curve, cooling
Supply temp
Setting range: -5 – 40 °C
Caution
Curve 0 must be selected for own curve to apply.
You can create your own cooling curve here, if there are
special requirements, by setting the desired supply temper-
atures for different outdoor temperatures.
Depending on which accessory is used the setting range
can vary.
MENU 4.2.3 - SG READY
Affect cooling
With low price mode of "SG Ready" and cooling operation
the indoor temperature is not affected.
With overcapacity mode on "SG Ready" and cooling opera-
tion, the parallel offset for the indoor temperature is de-
creased by "-1". If a room sensor is installed and activated,
the desired room temperature is decreased by 1 °C instead.
28
MENU 4.2.5 - SMART PRICE ADAPTION™
Affect cooling
Alternative: on/off
Degree of effect
Setting range: 1 – 10
This function can only be used if your electricity supplier
supports Smart price adaption™, if you have an hourly tariff
agreement and an active myUplink account.
Smart price adaption™ adjusts some of the heat pump's
consumption over the day to those periods with the
cheapest electricity tariff, which can give savings if on an
hourly rate based electricity contract. The function is based
on hourly rates for the next day being retrieved via myUplink,
and an Internet connection and an account for myUplink
are therefore required.
You can choose which parts of the installation are to be af-
fected by the electricity price and to what extent; the higher
value you select, the greater the effect the electricity price
has.
NOTE
A value that is set high may result in increased
savings, but may also affect the comfort.
MENU 7.1.2.2 - PP SP. HEATING MEDIUM GP1
Cooling
Speed during active cooling
Setting range: 1 - 100 %
Speed in passive cooling
Setting range: 1 - 100 %
Cooling
Speed during active cooling: Here, you set the desired pump
speed for active cooling.
Speed in passive cooling: Here, you set the desired pump
speed for passive cooling.
MENU 7.1.2.7 - PUMP SPEED BRINE
Make settings for the brine pump's speed here.
Speed in passive cooling
Setting range: 1 - 100 %
Speed during active cooling
Setting range: 1 - 100 %
Delta-T cooling
Setting range: 2 - 10 °C
Speed in wait mode, cooling
Setting range: 1 - 100 %
Speed in passive cooling: Here you set the speed at which
the brine pump will operate during passive cooling.