Herunterladen Inhalt Inhalt Diese Seite drucken

Outline Diagram; Electrical Connection - Nibe EME 20 Installateurhandbuch

Kommunikationsmodul
Vorschau ausblenden Andere Handbücher für EME 20:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Outline diagram

OUTLINE DIAGRAM, CONNECTION NIBE EME 20
Solar panels

Electrical connection

CONNECTING COMMUNICATION
NOTE
All electrical connections must be carried out by
an authorised electrician.
Electrical installation and wiring must be carried
out in accordance with the stipulations in force.
The heat pump must not be powered when in-
stalling NIBE EME 20.
To prevent interference, sensor cables to external connec-
tions must not be laid close to high voltage cables.
The minimum area of communication and sensor cables
to external connections must be 0.5 mm² up to 50 m, for
example EKKX, LiYY or equivalent.
NIBE EME 20 restarts after a power failure.
CABLE LOCK
Use a suitable tool to release/lock cables in terminal
blocks.
NIBE EME 20 S-series | GB
Heat pump /
indoor module or
control module
EME 20
Inverter
distribution unit
Internet
Energy meter
Electrical
own consumption
(optional)
Energy meter
network owner
3
1
1
4
1
2
myUplink
Own use
domestic
electricity
3
1
2
2
2
2
4
1
3
3
S
9

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis