IMPORTANT NOTICE

2.2 ADDITIONAL INFORMATION ABOUT SAFETY
!
D A N G E R
Hitachi is not able to foresee all the circumstances which may
result in a potential danger.
Do not pour water in the indoor or outdoor unit. These products
are fitted with electric components. If water comes into contact
with electric components, this will cause a serious electric
shock.
Do not handle or adjust the safety devices inside the indoor and
outdoor units. The handling or adjustment of these devices may
result in serious accident.
Do not open the service cover or access panel of the indoor and
outdoor units without disconnecting the main supply.
In the event of fire, switch off the mains, put out the fire
immediately and contact your service supplier.
Check that the earth cable is correctly connected.
Connect the unit to a circuit breaker of the specified capacity.
!
C A U T I O N
Refrigerant leaks may hinder respiration as the gas displaces the air
in the room.
If abnormality (burnt odor, etc.) occurs, stop the operation and
turn OFF the main power source immediately. If not, it may cause
breakage of the product, an electric shock or a fire. Contact your
distributor or contractor
3 IMPORTANT NOTICE
This air conditioner has been designed for standard air
conditioning for human beings. For use in other applications,
please contact your Hitachi dealer or service contractor.
The air conditioning system should only be installed by
professional installer, with the necessary resources, tools and
equipment, who are familiar with the safety procedures required
to successfully carry out the installation.
PLEASE READ AND FAMILIARISE YOURSELF WITH THE
MANUAL BEFORE STARTING WORK ON THE INSTALLATION
OF THE AIR CONDITIONING SYSTEM. Failure to observe the
instructions for installation, use and operation described in this
Manual may result in operating failure including potentially serious
faults, or even the destruction of the air conditioning system.
It is assumed that the air conditioning system will be installed
and maintained by responsible personnel trained for the
purpose. If this is not the case, the customer should include all
the safety, caution and operating signs in the native language of
the personnel responsible.
Temperature
Cooling operation
Heating operation
DB: Dry Bulb, WB: Wet Bulb
*The temperature may change depending on the outdoor unit.
2
PMML0552 rev.1 - 02/2021 - A10635790A
Fit the indoor unit, the outdoor unit, the remote control and the cable
at a minimum of 3 metres away from sources of strong radiation from
electromagnetic waves, such as medical equipment.
Do not use sprays, such as insecticides, varnishes or enamels or any
other inflammable gas within a metre of the system.
If the circuit breaker or supply fuse of the unit comes on frequently,
stop the system and contact the service suppler.
Do not carry out installation, maintenance or inspection work yourself.
This work must be carried out by qualified professional installer with
suitable tools and resources for the work.
Do not place any foreign material (branches, sticks, etc.) in the air
inlet or outlet of the unit. These units are fitted with high speed fans
and contact with any object is dangerous.
This appliance must be used only by adult and capable people,
having received the technical information or instructions to handle this
appliance properly and safely.
Children should be supervised to ensure that they do not play with
the appliance.
?
N O T E
The air in the room should be renewed and the room ventilated every
3 or 4 hours.
The system fitter and specialist shall provide anti-leak safety in
accordance with local regulations.
Do not install the unit in the following places, as this may lead to
a fire, deformities, rusting or faults:
Places where oil is present (including oil for machinery).
Places with a high concentration of sulphurous gas, such as
spas.
Places where flammable gases may be generated or circulate.
Places with a saline, acidic or alkaline atmosphere.
Do not install the unit in places where silicon gas is present. Any
silicon gas deposited on the surface of the heat exchanger will
repel water. As a result, the condensate water will splash out
of the collection tray and into the electrical box. Water leaks or
electrical faults may eventually be caused.
Do not install the unit in a place where the current of expelled
air directly affects animals or plants as they could be adversely
affected.
This heat pump air conditioner has been designed for the
following temperatures. Operate the heat pump air conditioner
within this range:
Indoor
Outdoor
Indoor
Outdoor
Maximum
32 DB
48 DB*
27 DB
15 WB*
(ºC)
Minimum
21 DB
-10 DB*
15 DB
-20 WB*

Werbung