10 Troubleshooting
9.2 Cutting torch
1 Check that all threaded fittings are tight and inspect wear parts for visible damage. Replace
if necessary.
2 The electrode must be replaced if the weld penetration is deeper than 1.5 mm.
3 Clean the cutting torch head regularly to remove cutting spatter.
4 Check the safety shut-off mechanism's contact pins to ensure that their spring function is
working properly. If required, clean the protective cap's contact ring to ensure a reliable
contact. Replace if necessary.
ABICOR BINZEL offers factory repair services.
10 Troubleshooting
DANGER
Risk of injury and device damage when handled by unauthorized persons
Improper repair work and modifications to the product may lead to serious injuries and
damage to the device. The product warranty will be rendered invalid if work is carried out on
the product by unauthorized persons.
• Only qualified personnel are permitted to perform work on the device or system.
Please observe the attached 'Warranty' document. In the event of any doubts and/or problems,
please contact your retailer or the manufacturer.
NOTICE
• Consult the documentation for the welding components.
EN - 28
®