7 Operation
7.2.2 Filtered compressed air free of oil and water
NOTICE
• Use only compressed air which is free from dirt, oil and water.
• We recommend:
• Initial filter with a 5 µm pore size
• Sub-micro filter with a 0.01 µm pore size
• 99.99% oil separation rate
• Air throughput at a flow pressure of 5.0 bar: ABIPLAS
Air throughput at a flow pressure of 5.0 bar: ABIPLAS
Air throughput at a flow pressure of 5.0 bar: ABIPLAS
 Tab. 3 Product-specific torch data (EN 60974-7) on page EN-6
7.3 Connecting the machine torch
NOTICE
• Observe and check the safety shut-off mechanism depending on the machine
configuration.
• Warning! Ensure that you connect the system externally.
7.4 Plasma cutting torch with central connector
NOTICE
• The plasma cutting torches with a central connector must only be connected to power
sources with central sockets which comply with the safety requirements according to
EN 60974-1 and EN 60974-7.
• The assignment of the cutting torch and cutting power source is clearly defined by the
codes on the plug and the socket and must be observed under all circumstances.
EN - 24
ABIPLAS
®
CUT 71 HF > 180 l/min
®
CUT 111 HF > 220 l/min
®
CUT 151 HF > 280 l/min
BAL.0716.0 • 2022-01-11
®