9 Maintenance and cleaning

Scheduled maintenance and cleaning are prerequisites for a long service life and trouble-free
operation.
DANGER
Risk of injury due to unexpected start
The following instructions must be adhered to during all maintenance, servicing, assembly,
disassembly and repair work:
• Switch off the power source.
• Close off the compressed air supply.
• Disconnect all electrical connections.
DANGER
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation and damage.
• Replace any damaged, deformed or worn parts.
WARNING
Risk of burns
The cutting torches reach very high temperatures during cutting.
• Allow the cutting torches to cool down.
• Wear the correct protective gloves.
NOTICE
• Always wear your personal protective equipment when performing maintenance and
cleaning work.
• Remove any adhering weld spatter.
• Ensure that all threaded fittings are tight.

9.1 Cable assembly

1 Check that all threaded fittings are tight and inspect wear parts for visible damage. Replace
if necessary.