A) Solvent temperature
and type the value in °C, then press key
°C
-Press key
B) Solid contents limit in %, over this value the regeneration will start
-Press P and type 10, type the needed value (decimals are automatic: ex. 65 to have
6,5%), press P to store
C) Working programs
Nine programs, with different data for thickness and plate feed, can be
To recall the program press P and type the number of the program to be used (from
01 to 09).Example:
- press P , type 01 for program no. 1, press key
mm/min., press key
- Press key
MEMO
again to store.
MEMO
mm
D) Rinsing solvent spraying time:
-press P 14, type the time from 0.5 to 5.5 seconds, press P again.
E) Rinsing solvent spraying gap
-press P 15, type the gap from 7 to 50 mm, press P again
F) To see how many plates have been processed:
-press P 13, read the information on display 8 and 7 , press P again.
G) To exclude the automatisms and set all the functions manually:
press RESET P 981944. In this condition it is possible to operate the single functions
by pressing the corresponding key, ex. to operate brushes rotation press
Press P 01 to escape
H) Solvent drum filling:
-enable the hand control (see G), press
J) Solvent drum emptying
-enable the hand control (see G), press
K) Calibration of the solid contents % device
- standard calculation values have already been set by the manufacturer in P88 and
P89. These values may not be precise enough. The computer has a program to allow
to recalculate the values through two easy operations:
1) as soon as the new solvent has been loaded, press P 90 % and wait for the end of
counting on display 7. Set the density of the new liquid, just tested, typing 1 (for
density 0,1). Press P to exit. These data will be stored in the program.
2) wash the plates until solvent density reaches 5,0 approx. (check with the manual
gauge). Press P 91 % and wait for the end of counting on display 7. Type the
measured density, 50 (for 5,0). Press P. Values in P88 and P89 will be modofied.
WASHOUT SETTING (open page 15)
again to store.
MEMO
mm /min.
, type the needed brush height in mm and tenth and press key
mm
°C
again to store
, type the needed speed in
MEMO
mm /min.
. Press P 01 to escape
. Press P 01 to escape
stored.