SAFETY
INFORMATION
These instructions for installation and use
are intended for the sauna owner or main-
tenance provider, as well as the electrician
responsible for installing the heater with
a sauna room indoor climate device. After
installing the heater with an indoor climate
device, the instructions must be handed
over to the owner or maintenance provider.
Table 1
Device
Saunum Professional
Saunum Professional
Saunum Professional
Saunum Professional
Saunum C Professional
Saunum C Professional
Saunum C Professional
Saunum C Professional
10
Before using the Saunum Professional
heater with an indoor climate device (here-
inafter 'sauna climate device'), read the in-
stallation and safety instructions. The sauna
climate device is intended for heating the
sauna room to 60–90 °C and for levelling
the sauna room climate during steaming.
Please note! The climate control unit
and the sauna heater must not operate
in temperatures exceeding 100 °C for
Leil control units, the operating tempe­
rature should not exceed 90 °C for all
other control units.
3 phase
POWER CABLE mm2
Power
PROTECTION
3 phase 1 phase / fan
12 kW
C 20 A
5 x 4
15 kW
C 24 A
5 x 4
18 kW
C 32 A
5 x 6
23 kW
C 40 A
5 x 10
12 kW
C 20 A
5 x 4
15 kW
C 24 A
5 x 4
18 kW
C 32 A
5 x 6
23 kW
C 40 A
5 x 10
NB! Do not use the sauna climate device
for any other purposes!
NB! To connect the sauna climate device to
the power network, a control device for the
control of electric heaters is required. The
control device must correspond to the pow-
er of the heater used according to Table 1.
The control device must have the ability to
control the fan of the sauna climate device,
and the function of simultaneously switch-
ing off the heater and the fan of the sauna
climate device is recommended.
The minimum height of the ceiling
5 x 1.5
2150 mm (short flue); 2350 mm
5 x 1.5
2150 mm (short flue); 2350 mm
5 x 1.5
2150 mm (short flue); 2350 mm
5 x 1.5
2150 mm (short flue); 2350 mm
5 x 1.5
2150 mm (short flue); 2350 mm
5 x 1.5
2150 mm (short flue); 2350 mm
5 x 1.5
2150 mm (short flue); 2350 mm
5 x 1.5
2150 mm (short flue); 2350 mm
To ensure the longevity of the device,
make sure that the continuous tempera­
ture of the sauna room, from the height
of the floor to the highest point of the
hot air outlet of the device, does not ex­
ceed 80 °C.
Cubic size of the
Minimum all around safe distance
sauna room
from the heater
250 mm
10–15 m3
250 mm
13–18 m3
16–22 m3
250 mm
250 mm
20–32 m3
250 mm
10–15 m3
250 mm
13–18 m3
250 mm
16–22 m3
250 mm
20–32 m3