SAFETY
INFORMATION
These instructions for installation and use
are intended for the sauna owner or main-
tenance provider, as well as the electrician
responsible for installing the heater with
a sauna room indoor climate device. After
installing the heater with an indoor climate
device, the instructions must be handed
over to the owner or maintenance provider.
Before using the Saunum Primary Set
heater with an indoor climate device (here-
DEVICE
POWER
4.5 kW
Saunum Primary Set
6 kW
Saunum Primary Set
9 kW
Saunum Primary Set
12 kW
Saunum Primary Set
4.5 kW
Saunum Primary Set B
6 kW
Saunum Primary Set B
Saunum Primary Set B
9 kW
10
inafter 'sauna climate device'), read the in-
stallation and safety instructions.
The sauna climate device is intended for
heating the sauna room at 60–100 °C and
for regulating the sauna room climate
during steaming.
NB! The climate control unit and the heat­
er of the sauna must not be operated in
temperatures exceeding 100 °C!
NB! Do not use the sauna climate device
for any other purposes!
The minimum
POWER CABLE mm2
3 phase
height of the
PROTECTION
3 phase
1 phase/fan
ceiling
C10
5 x 1.5
3 x 1.5
200 cm
C10
5 x 2.5
3 x 1.5
200 cm
C16
5 x 2.5
3 x 1.5
200 cm
C20
5 x 4
3 x 1.5
220 cm
C10
5 x 1.5
3 x 1.5
200 cm
C10
5 x 2.5
3 x 1.5
200 cm
C16
5 x 2.5
3 x 1.5
220 cm
NB! To connect the sauna climate device to
the power network, a control device for the
control of electric heaters is required. The
control device must correspond to the pow-
er of the heater used according to Table 1.
The control device must have the ability to
control the fan of the sauna climate device,
and the function of simultaneously switch-
ing off the heater and the fan of the sauna
climate device is recommended.
To ensure the longevity of the device,
make sure that the temperature of the
MINIMUM SAFE DISTANCE FROM THE HEATER
150 mm from sides, 150 mm from the front side, 1000 mm to the ceiling
(height from stones)
150 mm from sides, 200 mm from the front side, 1000 mm to the ceiling
(height from stones)
200 mm from sides, 250 mm from the front side, 1000 mm to the ceiling
(height from stones)
200 mm from sides, 300 mm from the front side, 1300 mm to the ceiling
(height from stones)
50 mm from sides, 50 mm from the front side, 1000 mm to the ceiling
(height from stones)
50 mm from sides, 50 mm from the front side, 1000 mm to the ceiling
(height from stones)
50 mm from sides, 50 mm from the front side, 1000 mm to the ceiling
(height from stones)
NB! The maximum temperature at the height of the temperature sensor of the controller (30+ cm from
the heater and 5 cm from the ceiling) is 100 °C.
sauna room at the height of the lower
part of the device does not exceed 80 °C.
If it is exceeded, the thermal protection will
be applied and the fan will stop; the fan
will start running again if the temperature
drops below the fuse limit of application.
The manufacturer is not responsible for any
malfunction caused by an overrun of the
authorised operating temperature.
CUBIC SIZE OF THE
SAUNA ROOM m3
3–5
5–7
7–10
10–13
3–5
5–7
7–10
11