BEFORE THE
INSTALLATION
The installation of the sauna climate device
must be performed by a qualified electri-
cian. The connection of the device must be
performed in a stable location with a cable
that meets the temperature conditions.
Protective earthing (PE) must be connected
to the connection terminal of the device,
with the cross-sectional area of the cable
being at least 2.5 mm2. The device must be
powered from the control device's supply
circuit, which is protected by over-current
fuses. The required over-current fuses sizes
and the connection cables dimensions are
given in Table 1 (see pages 10–11).
All the certified sauna control devices with
the operating capacity corresponding to
the capacity of the Saunum Professional
model used in accordance with Table 1 (see
pages 10–11) may be used to control the
sauna climate control device.
Before starting the installation work,
read the installation instructions and
observe the following:
• The power and type of the heater are
suitable for the given sauna room.
The recommended sauna room
volume is given in Table 1 (see pages
10–11).
• The supply voltage is suitable for the
sauna climate device.
• At the installation site of the sauna
24
climate device, the minimum safety
distances given in Table 1 (see pages
10–11), measured from the heater
housing, are guaranteed.
• The dimensions of the device are
shown in Figure 4.
• It must also be ensured that the
upper edge of the fan outlet of the
sauna climate device is lower than
the lower edge of the bench.
• There must be no obstructions in
front of the air outlet from the device,
the exhaust air flow must be able to
flow freely across the sauna room.
• The device works most efficiently
when there is a gap between the flue
top and the ceiling (see figure 2) and
the exhaust air is blown under the
bench.
• Safety distances must be complied
with unconditionally, as failure to do
so may result in a fire hazard. Only
one sauna climate device may be
installed in the sauna room.
419 mm
750 mm
600 mm
105 mm
Figure 4
25