Preparing for use / Advice on use / Cleaning

Preparing for use

Connecting the compressed
air source
Note: The air sander must be operated using
cleaned and condensate-free compressed air only
and its maximum allowable working pressure of
6.3 bar at the device must not be exceeded.
Note: The compressed air source must be fitted with
a (filter) pressure reducer so that the air pressure can
be regulated.
Connect the plug nipple
coupler to the compressed air supply.

Switching on and off

Note: Always switch on the air sander before
bringing it into contact with the workpiece material.
Switching on the air sander:
Press the operator's lever
(see Fig. C).
Set the speed using the speed control
Switching off the air sander:
Release the operator's lever
After you finish work, disconnect the device
from the compressed air source.
Note: First disconnect the hose from the com-
pressed air source (compressor) and only then
disconnect the compressed air supply hose
from the device. This will ensure that the com-
pressed air supply hose does not wave around
in an uncontrolled manner.

Advice on use

Wait until the device has come to a standstill
before you put it down.
12
by a quick-release
3
fully down
1
.
5
.
1

Sanding surfaces

Switch the air sander on and bring the whole
of its sanding area into contact with the surface
to be abraded. Move it using even pressure to
and fro over the workpiece (see Fig. D).
Note: The sanding output and appearance are
largely dependent on the choice of sanding
sheet and the pressure applied. A sanding sheet
must be free of defects to produce a good
sanding output.
Ensure that you use an even pressure. Excessive
pressure does not produce a higher sanding out-
put, it just increases the wear on the sanding sheet.
A sanding sheet previously used on metal must
not be used on other materials.

Replacing the backing plate

RISK OF INJURY! Always
disconnect the device from the compressed air
source before you replace the backing plate
Push the open-ended spanner
backing plate
and collar
6
Release the backing plate
plate anticlockwise and holding the open-ended
spanner
still against this movement.
11
Screw on a new backing plate
until tight while holding the open-ended span-
ner
still against this movement.
11

Cleaning

RISK OF INJURY! Always
disconnect the device from the compressed air
source before you clean it.
Clean the air sander after you have finished
using it.
Store the air sander in dry enclosed rooms only.
Use a dry cloth to clean the device. Under no
circumstances should you use petrol, solvent or
cleaners which attack plastic.
Keep the ventilation openings clear at all times.
Remove dust clinging to the sander
with a brush.
.