Connecting the device to the power grid

4.2.1 Configuring the AC connection plug
3
2
1
4
Fig. 2: AC connection plug
1 Nm
1 Nm
Fig. 5: Tighten screws on the housing
↻ Connection area opened.
1 Slide the cable fitting over the cable.
2 Select seal according to cable diameter used.
3 Slide the housing and seal over the cable.
4 Remove the insulation from the cable. [sl. 50 mm]
5 Shorten the wires N, L1 by 8 mm if a single-phase connection is present or shorten the wires N, L1, L2, L3 by the
same length in case of a 3-phase connection.
6 Strip the wires N, L1 in case of a single-phase connection or N, L1, L2, L3 in case of a 3-phase connection by 12 mm.
7 Flexible wires must be fitted with wire sleeves in accordance with DIN 46228.
8 Insert wires into the contacts in accordance with the markings on the contact carrier.
9 Tighten screws on contact carrier. [
10 Press contact carriers into the housing with an audible "click".
11 Secure the housing with a screwdriver [
» Make the electrical connections.
4.2.2 Make the grid connection
Make the grid connection
↻ AC connection plug configured correctly.
1 Insert the AC connection plug into the device connector on the device.
ð NOTE: The AC connection is secure when an audible click is heard.
2 Lay the cables correctly and in accordance with the following rules:
- Lay the cables around the device with a minimum clearance of 20 cm
- Never lay cables over semiconductors (cooling bodies)
- Excessive bending force may negatively impact the protection rating. Lay the
cables with a bending radius of at least 4 times the cable diameter.
» The device is connected to the power grid.
Photovoltaic feed-in inverter KACO blueplanet 3.0-10.0TL3
1,97 In
50 mm
(50mm)
6
0,47 In
12 mm
(12mm)
0,31 In
8 mm
(8mm)
5
Fig. 3: Strip the insulation from the
cable
30
6,5 Nm
Fig. 6: Tighten the cable screw fitting
S_2/
1 Nm]
W_29] and tighten the cable screw fitting. [
N
PE
L1
L3
L2
N
PE
L1
L2
Fig. 4: Connect wires to the contact
carrier
Fig. 7: Press contact carrier into the
housing
W_29/
4 Nm]
Fig. 8: Engage the AC connector
with the device connector
L3
Page 7