Herunterladen Inhalt Inhalt Diese Seite drucken

Mounting; Wall Attachment; Final Assembly - Honeywell aP Montage, Anschluss, Anleitung

Blockschalter mit mechanischer zuschließsperre
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Mounting and Connection Instructions Block Switch
6.

Mounting

6.1
Open housing
Handle with care to avoid damaging protection against drilling.
Note:
The numbers in ( ) in the following sections refer to the illustration on the left ("5. Set up").
If there is no locking cylinder, point 3 is inapplicable.
1. Screw off front plate (1).
2. Remove seal.
3. Insert key and turn 90° to the right f
4. Remove mounting plate (11).
5. Loosen the fixing screw for the protection against drilling (17) and pull the clip (20) to
release.
6.2

Wall attachment

The housing is fixed to the wall by 3 boreholes (2) and appropriate screws and plugs. Ensure
that the mounting surface is firm and flat.
6.3

Final assembly

Mount the top of the housing after connecting.
-
If still required, insert locking cylinder (12) as per the adjoining illustration (Chapter 5) and
screw tight.
-
Check the position of the key bit and correct, if necessary (14).
-
Insert the internal housing with protection against drilling (16) on the PCB and screw tight.
-
Insert the key in the profiled semi-cylinder and turn the key 90° to the right from the center
position.
-
Place mounting plate (11) as well as seal and front plate and screw to the housing.
-
Ensure that the cover contact screw (15) activates the cover contact switch (4).
-
Carry out a
function check
rom the "OFF" position (disarmed)
under operating conditions.
.
13

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

21130Up21131

Inhaltsverzeichnis