Herunterladen Inhalt Inhalt Diese Seite drucken

Function; Locking Cylinder - Honeywell aP Montage, Anschluss, Anleitung

Blockschalter mit mechanischer zuschließsperre
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Mounting and Connection Instructions Block Switch
3.

Function

A separate operating voltage is not required for the block switch. It is, therefore, especially suit-
able for applications that have no permanent operating voltage.
-
The key position "ON(EIN) / OFF(AUS) " is scanned by a micro pushbutton.
-
The red and green LEDs are actuated by the connected intrusion detection central unit.
-
The monitoring resistors are located on the solder supports so that the
to the different types of central control unit is possible.
Acknowledgement during arming/disarming:
Successful arming/disarming is acknowledged by an
time-limited signal.
The LED lights up during arming/disarming.
If
arming
If the central control unit does not transmit an acknowledgement signal, the block
coil cannot be actuated. In this case, there is no release.
Do not turn the key by force!
4.

Locking cylinder

The block switch is designed for profiled semi-cylinders with key bit position of 90° to the right.
Note:
Due to technical differences in locking cylinders of different manufacturers, the locking cylinder
must be chosen with care. The length A (see illustration) should be 30 mm. We recommend
using the profiled semi-cylinder Item no. 028032.
is not possible, the key cannot be turned fully.
A
A
LED
from the central control unit with a
10±1
10±1
Key bit position 90° to the right
11
required adaptation

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

21130Up21131