(Table 10) BURNER FEATURES (NL - CAT. II
Gas type
Liquid gas LPG
(G30-G31)
Natural gas
(G25)
Liquid gas LPG
(G30-G31)
Natural gas
(G25)
WARNINGS
General
 Read the instructions carefully before installation, use and maintenance of the appliance.
 The installation has to be performed by qualified personnel following the manufacturer's
instructions given in the provided manual.
 The appliance is suitable only for preparing and cooking food in commercial kitchens such as
those used in restaurants, hospitals, company canteens, cooking centres, butcher's shops and
food production firms. Any other type of use is not in accordance with the intended purpose and
could place people and/or objects at risk.
 The griddle plate is equipment suitable to grill meat, fish, vegetables, eggs.
 The appliance should only be used by trained personnel and for the use for which it was
designed.
 Due to the nature of the appliance, the temperatures required for cooking may cause various
areas of the panelling, as well as kitchenware, to become hot. This is not a construction defect,
but a physical phenomenon caused by the chemical and physical properties of the materials used
for the construction of the appliances.
 In the event of breakdown or malfunction, switch off the appliance and seek help exclusively
from an authorized technical assistance centre.
 Only use genuine spare parts; otherwise no liability is assumed by the manufacturer.
 The appliance must not be washed with high pressure water sprays; the vents or inlets/outlets for
air, fumes and heat must not be obstructed.
 Before connecting the appliance make sure that the plate specifications correspond to the gas and
electrical supply.
 ATTENTION: The cooking plate must not be cooled down hard (i.e. cooling it down by ice or
cold water); otherwise there is a danger of cracking the cooking plate itself.
 When not in use, make sure the appliance is disconnected from the electric mains.
ATTENTION! The manufacturer declines any liability for damage caused by wrong
installation, tampering, making unauthorized changes, improper use, poor maintenance,
installation of non-original spare parts, not observing local norms, incorrect use or not
observing the instructions in this booklet.
Nominal capacity
Reduced capacity
[kW]
[kW]
GRIDDLE PLATE BURNER ½ module
8.00
3.00
8.00
3.00
GRIDDLE PLATE BURNER 1 module
8.00x 2
3.00 x 2
8.00x 2
3.00 x 2
Diameter of main
By-Pass diameter
injectors
[1/100 mm]
[1/100 mm]
AL145
AL220
AL145 x 2
100 x 2
AL220 x 2
150 x 2
Pag. 41/68
)
2L3B/P
Pilot injectors
[N°]
100
30
150
51
30 x 2
51 x 2
Air regulation
"x"
[mm]
30.0
15.0
30.0
10.0

Werbung