Dehumidifier DT 760
CAUTION
Risk of injury from tipping device
There is a risk of injury, if the device tips over or
falls during transport.
a) Wear safety footwear and protective gloves.
b) Always move the device by its handle and on
its castors.
a) Check the delivery for completeness.
Report any transport damage or incomplete
delivery to your dealer.
b) Dispose of the packaging in accordance with
the applicable statutory regulations.
c) Mount the handle and the castors, using the
supplied installation kit.
Tighten all screws firmly.
d) If necessary, lift the device by its handle and
then place it on the ground.
e) Observe the permissible Operating conditions
[
32].
f) Make sure that the condensate tank is
properly positioned in the device.
g) If the condensate is to drain off into a floor
drain, connect the condensate discharge hose
to the adapter provided at the rear of the de-
vice.
h) Make sure that a clean and intact filter is in-
stalled in the filter holder in front of the air in-
let slits.
i) Make sure that the power cable is free of de-
fects.
j) Connect the power plug to an earthed mains
socket with appropriate fuse (see Technical
details
[
48]).
k) If necessary, check and record the operating
hours shown on the display.
l) If necessary, check and record the power me-
ter reading (at the rear of the device).
38 / 52
 The device is now correctly assembled and
ready for operation.

Positioning device in the room

– To correctly position the device in the room,
observe the following:
– For best performance, the device should be
operated in enclosed rooms.
– Close all windows, doors, etc. to prevent hu-
mid and dry air from mixing.
Open doors only, if this is absolutely neces-
sary. By keeping doors and windows closed,
you create an enclosed drying chamber.
– With this chamber, the air should be able to
circulate freely. Doors inside the drying cham-
ber should be kept option. To ensure proper
air circulation throughout the drying chamber,
use an air blower or fan.
– Run as many devices as are necessary for a
threefold air change.
– Position the device so that its air inlet and out-
let are not blocked.
– Avoid positions close to loose material, cur-
tains, etc.
– Place the device in the centre of the room.
– To dry a particular area: Position the device so
that the air outlet faces the wet area. The dry,
warm air then helps eliminating moisture.
The air inlet should be at a distance of mini-
mum 1 metre from a wall.
– During dehumidifying, the air in the room is
heated. In small rooms, this can substantially
increase the room temperature.
As a rule, room temperature between 20 °C
and 27 °C provide the best conditions for ef-
ficient drying. The room temperature must not
exceed 38 °C or drop below 1 °C, as the de-
vice is otherwise unable to work properly (see
also Technical details
[
48]).