Instructions for operation

During operation observe the following general
rules:
– All work on the device must be performed by
an instructed person.
– Do not modify, dismantle or disable safety de-
vices. The safety devices must be inspected at
regular intervals.
– All the covering panels, covers and hoods must
be installed as intended.
– Structural modifications to the device are not
allowed.
Maintenance and troubleshooting
instructions
For maintenance and troubleshooting observe the
following general rules:
– Only suitably qualified staff may perform this
work on the device.
– The device must be switched off and the pow-
er plug must be disconnected from the mains
socket.
13.1

Operating conditions

The device is intended for mobile or stationary use
indoors, on construction sites, in garages and
storage spaces / rooms. The device operates effi-
ciently:
– Within a temperature range from 5 °C to
+35 °C and at 40 % to 100 % relative humidity
– In closed rooms where there is as little air ex-
change as possible
– If it is placed as centrally as possible in the
room and
– the dry air is discharged towards the wet part
of the room
32 / 52
NOTICE
Optimal moisture extraction and room
temperature
In smaller rooms, the room temperature may be
significantly increased by the operation of the
condensation dryer. Room temperatures between
20°C and 27 °C offer ideal conditions for oper-
ating the device.
In addition, comply with the following conditions
and safety instructions:
– Always handle the device with care. Never
drop the device, do not throw it or transport it
unsecured.
– The device must be installed upright and sta-
ble.
– The air must be able to circulate freely (keep a
free space of at least one metre around the
device).
We recommend operating the device in con-
junction with fans to ensure maximum air cir-
culation.
– Do not cover the device during operation.
– Ensure that the condensate can always run off
safely into a drain or a suitable vessel. Vessels
used for collecting the condensate must be
emptied regularly.
– Never drink any condensate that may accumu-
late, there is a danger of infection.
– The device must not be operated in puddles or
in stagnant water. If the device or the connec-
tion cable gets wet then it must be dried thor-
oughly before the device may be operated.
– Make sure that the device does not suck in
any oil, grease or other contaminant.
– Only use the device with a clean air filter.
– The mains voltage must correspond to the de-
tails on the rating plate.
EN