The condensate pump is controlled by a float
switch. When the condensate in the condensate
tank reaches the float switch level, the pump
starts and conveys the condensate through the
discharge hose to a drain or into a collecting ves-
sel. The pump stops as soon as the float switch is
no longer triggered.

Automatic defrosting

During prolonged operation (continuous operation
at a room temperature of below approx. 20 °C),
ice builds up at the evaporator. A temperature
sensor monitors the frost temperature, and the
device control initiates a defrosting cycle when
the need arises. During the defrosting process, the
evaporator is heated. During automatic defrost-
ing, large amounts of condensate are produced.
As soon as the evaporator is free of ice, the device
starts returns to dehumidifying operation.
NOTICE
Condensate
The amounts of condensate and ice produced by
the device depend on the actual operating condi-
tions (air temperature and air humidity).
The performance of the device should be primari-
ly determined by the rate at which it reduces the
air humidity and not by the amount of water ex-
tracted from the air. To measure the humidity in
the air, use a thermo hygrometer.
14.2.1

Intended use

The device is intended exclusively for dehumidify-
ing air in enclosed rooms at atmospheric pressure.
Proper use of the device is only possible, if all
persons who operate it have read, understood and
adhere to the operating instructions. Proper use
also includes strict adherence to the operating
conditions (see Operating conditions
device must be tested and serviced at regular
intervals.
EN
The device is solely intended for industrial and
commercial use.
Any other use is deemed improper. Improper use
shall void all warranty.
See also
 Technical details
14.2.2
The following types of misuse are foreseeable:
– Drying air in rooms that are not enclosed, or in
– drying air without adhering to the specified
14.3
If the safety devices are not properly installed and
configured, there is a risk of serious injury to per-
sons. Do not modify, dismantle or disable safety
devices. All the safety devices must be freely ac-
cessible at all times.
Familiarise yourself with all safety devices; this
way personal injury and/or damage to property
can be prevented or minimised.
The following illustration shows the safety devices
of the dehumidifier.
2
[
32]). The
Fig. 13:
[
48]

Foreseeable misuse

outdoor areas,
minimum spacing and operating conditions.

Safety devices