and the FULL indicator on the display flashes
at intervals of 10 seconds.
Press the PUMP button again to start the con-
densate pump. The pump should always be
started to test the device prior to running it,
and before moving the device to a different
room.
– ON/OFF indicator – operating status indica-
tor (ON or OFF): The ON/OFF indicator is lit
in green when the device is switched on.
– ALARM indicator: If there is a fault or an
alarm signal, the ALARM indicator is lit in red
(see also Malfunctions during operation
– Display – display of set parameters and op-
erating status: After connecting the power
plug to a mains socket, the version number of
the device software is displayed for approx.
4 seconds.
Other display messages:
Action
Message / description
none
rH xx:
Display of relative air humidity
Full:
Condensate tank is full
Defr.:
Automatic defrosting in progress
Press SET + or
Target value for humidity control
SET – button
Cont:
Continuous dehumidifying
rH xx:
Hygrostat-controlled operation
Press HOURS
Xxxx:
button
Display of operating hours
– WORK indicator – operating and break times
(only in operation when device is running): If
the indicator is off, the device is in break mode
(e.g. target air humidity has been reached). If
the indicator flashes, the device has been
EN
switched on and waits for the compressor to
be ready (duration up to 210 seconds) or is in
defrost mode.
– FULL indicator – condensate tank level indi-
cator: When the condensate tank is full, the
FULL indicator is lit in red.
– Resetting alarm: Switch off the device by
pressing the ON/OFF button and then press
and hold the HOURS and SET + buttons for 10
seconds. All alarm signals are reset.
15
[
41]).
The device has been assembled, set up and tested
at the factory. In order to rule out any life-
threatening injuries and damage to materials dur-
ing transport and installation, please observe the
following:
– Transport and installation work may only be
carried out by qualified and authorised per-
sons.
– Make sure that the transport routes are large
enough for the device.
DANGER
Danger to life from electric shock
Touching electrically powered parts can be fatal.
a) Before moving the device, switch it off and
disconnect the power plug from the mains.
b) Never pull the device by the power cable; al-
ways hold it by the handle provided.
Dehumidifier DT 760
Transport and
installation
37 / 52

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Diese Anleitung auch für:

1110588

Inhaltsverzeichnis