Herunterladen Inhalt Inhalt Diese Seite drucken

Connecting Cash Dispensers To Sistore Mx; Interface Configuration - Siemens RCI 0601 Benutzerhandbuch

Mx multi-channel box
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Connecting cash dispensers to SISTORE MX

10
Connecting cash dispensers to SISTORE MX
10.1

Interface configuration

50
Siemens Building Technologies
Fire Safety & Security Products
Prerequisite:
When connecting cash dispensers to SISTORE MX, one MX Multi-Channel
Box is required for each cash dispenser.
When connecting cash dispensers to SISTORE MX, proceed as follows:
1.
Contact the manufacturer of the cash dispenser or your customer for
information on the interface configuration.
Interface configuration: Baud rate, data/stop/parity bit(s).
2.
If no information on the CDM interface is available, check the interface using
the logging mechanism.
Open the .ini file.
Check the interface parameters under Format (see Section 9.4). See
Section 10.1: Schnittstelleneinstellung.
Enter the correct cash dispenser type. If no type is entered, the interface
will be ignored.
The following interface configurations are the most commonly used:
SNI CDM (for SNI, SNI_DREBA and SNI_PBM)
2400 baud, 8 D-bits, 1 stop bit, none parity
9600 baud, 8 D-bits, 1 stop bit, none parity
IBM and NCR CDM
1200 baud, 7 D-bits, 1 stop bit, odd parity
9600 baud, 8 D-bits, 1 stop bit, none parity
ASCOM CDM
9600 baud, 7 D-bits, 1 stop bit, odd parity
06.2006