Installation
7
Installation
7.1
Cable connection
7.1.1
Terminal assignment
36
Siemens Building Technologies
Fire Safety & Security Products
Use the following screw types for mounting the plastic housing
on metal surfaces:
on wooden surfaces: four wood screws Ø 3.5 x 20
on concrete / walls:
(screws are not included in the scope of supply).
1.
Remove the cover to open the housing.
2.
Lead the cables in through these cable glands.
3.
Connect the cables as described in Section 7.1: Kabel anschließen.
4.
Set the dip switches as described in Sections 8.1: Adresse einstellen and 8.2:
Baudrate einstellen.
5.
Replace the cover to close the housing.
1.
Connect the MX Multi-Channel Box to the power source.
When connecting the device to a plug-in power supply (2GF1800-8BE, not
included in the delivery) make sure the polarity is correct.
2.
Connect the cable to the terminals 1, 2 and 3, 4 DC 12 V. See Tab. 1:
Beschreibung der Klemmen.
3.
Connect the cash dispensers via the RS232 interface. See Section 7.1.2:
RS232-Schnittstelle (GAA-Schnittstelle).
4.
Connect the SISTORE MX via the RS485 interface. See Section 7.1.3:
RS485-Schnittstelle (MX-Schnittstelle).
Terminal
Description
1
+12 V DC supply voltage
2
+12 V DC supply voltage (internally connected to terminal 1)
3
0 V DC supply voltage ground
4
0 V DC supply voltage ground (internally connected to terminal 3)
5
RS232 TXD
6
RS232 RXD
7
0 V DC (internally connected to 3, 4)
8
RS485 T-
9
RS485 T+
10
0 V DC (internally connected to 3, 4)
11
+ TTY Out
12
TTY Out
13
0 V DC (internally connected to 3, 4)
14
0 V DC (internally connected to 3, 4)
Terminal assignment
Tab. 4
four screws M4 x 16
four wood screws
Ø 3.5 x 40 with plug Ø 5
06.2006