Herunterladen Inhalt Inhalt Diese Seite drucken

Configurable Status Flag; Time Synchronization; Configurable Step For Time Synchronization - Siemens RCI 0601 Benutzerhandbuch

Mx multi-channel box
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Connection of MX Multi-Channel Box to SISTORE MX and SISTORE MX Pro
9.11

Configurable status flag

9.12

Time synchronization

9.13

Configurable STEP for time synchronization

48
Siemens Building Technologies
Fire Safety & Security Products
Each time a cash dispenser is started an initialization string is sent over the
camera interface which has to be acknowledged by a status flag sent by SISTORE
MX. If this status flag does not correspond with the status flag the cash dispenser
expects, then the cash dispenser will completely deactivate the camera interface.
Older CDMs use the status flag 1010 while newer models use 0000.
STATUSFLAG=0000
If several cash dispensers are connected to one SISTORE MX system, this
parameter can be used to define by which cash dispenser the SISTORE MX will be
synchronized.
It is recommended to activate the time synchronization only on one interface.
.ini file:
ZEITSYNC_COMNR=1 // time synchronization will take place over this interface
Both the fixed field and the variable field (if provided) contain the current date and
time.
The positions where the current date and time are expected can be defined using
the telegram configuration in the .ini file. Usually, several telegrams containing the
relevant date and time will be sent during a transaction. If the date and time
contained in the fixed field are to be used, the step by which time synchronization
will be performed can be determined using the parameter ZEITSTEP. This is to
ensure an optimum synchronism between the SISTORE MX archive and the cash
dispenser log.
ZEITSTEP=11
// time synchronization will be performed by this STEP