5168; EN/IEC 60704-1; EN/IEC 60704-2-13; EN/IEC 60704-3;
ISO 3741; EN 50564; IEC 62301.
• EMC: EN 55014-1; CISPR 14-1; EN 55014-2; CISPR 14-2;
EN/IEC 61000-3-2; EN/IEC 61000-3-3. Suggestions for a
correct use in order to reduce the environmental impact:
Switch ON the hood at minimum speed when you start
cooking and kept it running for few minutes after cooking is
finished. Increase the speed only in case of large amount of
smoke and vapor and use boost speed(s) only in extreme
situations. Replace the charcoal filter(s) when necessary to
maintain a good odor reduction efficiency. Clean the grease
filter(s) when necessary to maintain a good grease filter
efficiency. Use the maximum diameter of the ducting system
indicated in this manual to optimize efficiency and minimize
noise.
Use
The hood has been made for use in the internal recirculating
filtering version.
Cooking fumes and steam are aspirated inside the hood,
filtered and cleaned, passing through the fat filter/s and the
carbon filter/s that MUST be supplied with the hood.
Mounting
Before beginning installation:
Check that the product purchased is of a suitable size for
the chosen installation area.
Remove the charcoal (*) filter/s if supplied (see also
relative paragraph). This/these is/are to be mounted only
if you want lo use the hood in the filtering version.
Check (for transport reasons) that there is no other
supplied material inside the hood (e.g. packets with
screws (*), guarantees (*), etc.), eventually removing
them and keeping them.
This type of cooker hood must be fixed to the ceiling.
Very heavy product; hood handling and installation must
be carried out by at least two persons.
Expansion wall plugs are provided to secure the hood to
most types of walls/ceilings. However, a qualified technician
must verify suitability of the materials in accordance with the
type of wall/ceiling. The wall/ceiling must be strong enough to
take the weight of the hood.
Do not tile, grout or silicone this appliance to the wall.
Surface mounting only.

Operation

This product is designed to work with an Elica remote control,
either supplied with the product or purchased separately as an
optional.
To control the hood via remote control, the affiliation
procedure must be carried out.
CAUTION!
To begin, the hood must be disconnected and then
reconnected to the power supply and the affiliation procedure
must be carried out within the first minute of connection to the
power.
Read the instructions supplied with the remote control, which
provide detailed instructions on affiliation and correct use.
Note: Using the remote control, delayed shut-down can be
programmed based on the aspiration speed (power) enabled
at that moment:
Speed 1 (low aspiration): 20 minutes
Speed 2 (medium aspiration): 15 minutes
Speed 3 (high aspiration): 10 minutes
Control panel on hood
T1. Suction speed (power) control key.
38