Taking Into Operation For The First Time; Operation With Preheated Water; Special Accessories - STIEBEL ELTRON DEL 18 Si Gebrauchs- Und Montageanweisung

Elektronisch geregelter durchlauferhitzer
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

L
– Priority circuit
in combination with
other electrical units, such as electric stor-
age heaters, the load-shedding relay is to be
used:
a Load-shedding relay (see "2.15 Special
Accessories").
b Control line to the switching contactor of
the second unit (e.g. electric storage
heater).
c Control contact, open when the DEL
electronic is switched on.
Load-shedding takes place when the DEL
electronic unit is in operation.
The load-shedding relay may only be
connected to the middle phase of the
unit terminal strip.
• Connection in the lower unit area
In the delivery state, the unit is prepared for
the electrical connection to be in the lower
part of the unit.
– Set the unit up as shown in the illustration.
– To provide a seal against water penetration,
the cable grommet (33) provided must be
used.
– Connect the connection lead to the termi-
nal block.
• Connection in the upper part of the unit
Preparing the unit for electrical connection at
the top:
– Knock out the infeed aperture marked out
in the rear wall (a) of the unit.
– Shorten the cable grommet (b) for the seal,
wet with a rinsing agent on the inside to
provide a better fit (sliding capacity), and
install in the rear wall (c).
– Release the plastic profile strip (d).
– Release the terminal block (e).
– Fit the terminal block in the upper part of
the unit (f). Care must be taken to ensure
that the switch lead wires do not project
over the rear wall of the unit.
– Fit the plastic profile strip (g).
Carrying out the electrical connection
To provide protection against water pen-
etration, the cable grommet provided (c)
and the plastic profile strip (g) must be fitted
and the dimensions properly respected.
– Connect the connection lead to the termi-
nal strip.
2.12 Completing installation O
1. Open the three-way isolating valve (a)
2. Fix the lower part of the rear wall (b)
3. Fit the lower securing screw (c).
4. For surface screw connection only
Knock out the passage apertures (a) in the
cover in an appropriately clean manner, or
use a file. The guide pieces (b) provided
with the unit must be engaged in the
apertures.
5. For under-sink installation only
Shift the snap nut (a) from the bottom to
the top. Remove the control panel (b)
from the cover, unscrewing the screws in
the cover for this purpose. Rotate the
cover, lay in the control panel and secure
with the screws.
6. If required, activate the temperature miter
G
(see "2.9 Temperature Limitation").
14
2.13 Taking into operation
for the first time Q
(This may only be done by a qualified installer)
In normal operation the LED ///
flashes (15, see also „4. Fault
elimination").
Fill the unit and bleed it of air;
1
ensure there is no risk of dry
2
running.
3
Open and close all the attached hot
water fittings several times, until the
4
pipe network and the unit are free of
5
air. With regard to air, see under
6
"2.2 Important Notes".
1
7
Activate the safety switch
2
!
M
The DEL electronic is supplied with the
8
3
1
safety switch activated (press the blue
9
4
1
reset button in).
2
10
1
5
2
1
Insert the plug of the setpoint
3
1
11
2
sensor cable to position X 1.
6
2
3
4
2
12
3
Fit the cover and secure it with
7
3
4
5
3
screws.
4
13
4
8
5
6
4
Connect the network voltage.
5
14
5
9
6
7
5
Check the functioning of the
6
6
15
10
7
8
N
instantaneous water heater.
6
7
7
16
11
8
9
Pull the protective foil off the
7
8
8
17
9
12
10
control unit.
8
9
9
18
10
11
13
Handing over the unit:
9
10
10
19
12
11
14
Explain to the user how the unit works and
10
11
11
acquaint them with the instructions for use.
20
13
12
15
12
11
Important notes:
12
14
21
13
16
• Advise the user about possible risks
13
12
13
15
22
14
17
(scalding).
14
13
14
16
• Hand over these instructions, which are to
23
15
18
15
14
15
be kept in a safe place.
17
24
16
19
16
15
16
18
17
2.14 Operation with pre-
17
20
16
17
19
18
18
heated water
21
17
18
20
19
19
The DEL electronic unit allows for reheating
22
18
19
21
20
of the incoming water up to a maximum of
20
23
19
20
22
60 °C.
21
21
24
20
21
23
If the incoming water is already at
22
22
21
more than 55 °C, it will not be heated.
22
24
23
23
A maximum incoming temperature of
22
23
24
24
60 °C can be guaranteed by installing a
23
24
central thermostatic fitting (see "2.15
24

Special Accessories").

2.15 Special accessories
Two-handle pressure fittings
– Kitchen fitting WKMD
P
:
Order No. 07 09 17
– Bath fitting WBMD
Order No. 07 09 18
Set of two water plugs
Order no. 07 43 26
Required in the event of third-party
D
:
pressure fittings (
Installation set for surface installation
Order No. 07 40 19
- 2 water plugs G ½
- 2 union nuts ½" with insert for 12 mm Ø
soldered joint.
Not required in the case of the Stiebel
Eltron WKMD and WBMD fittings.
I
, 30).
Load-shedding relay LR 1-A
Order No. 00 17 86
Priority circuit for the DEL electronic , with
simultaneous operation of, for example,
electric storage heaters.
For connection of LR 1-A, see
Remote control FS 1
for DEL
electronic operation.
Setting button for installation in a concealed
socket.
Order No. 16 73 30
With a remote control unit installed, operation
is only possible with the FS 1 remote control
unit.
The remote control unit is operated with
safety extra-low voltage. Suitable connection
leads (without metallic screening) are, for
example, NYM 3 x 1.5 or J-YY 2x2x0.6 (tel-
ephone line).
Fixed-position laying of the control lead, on
the surface or concealed, in position
permissible.
No screened cable may be used in protec-
tion area 1.
Accessories for operating a DEL
electronic with pre-heated water
– Central thermostatic fitting ZTA 3/4
Order No. 07 38 64
The central thermostatic fitting installed
directly above the storage unit ensures, by
adding cold water via a bypass line, that the
output temperature of 60 °C will not be
exceeded.
Service monitor
Order No. 16 77 41
Diagnostic unit for fault recognition in the
DEL electronic .
Universal installation frame
Order No. 07 37 90
With rear wall and electrical wiring.
This module creates a hollow space be-
tween the rear wall of the unit and the
installation wall. This allows for a concealed
electrical connection to be fitted at any
desired point behind the unit. The depth of
the unit is increased by 30 mm. The protec-
tion mode will be changed by the addition
of the module, to IP 24 (spray water pro-
tected).
Pipe module offset installation
Order No. 07 39 17
Pipe module offset installation, including
universal installation frame, Order -
No. 07 37 90. Vertical displacement of the
unit in relation to the water connection by
90 mm downwards. The depth of the unit
will be increased by 30 mm. The protection
mode will be changed by the addition of
the module, to IP 24 (spray water pro-
tected).
Pipe module installation below
working surface
Order No. 07 05 65
Connections: Surface installation, G 3/8,
top.
L
.
N
(a) is

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Del 21 siDel 24 siDel 27 si electronic lcd

Inhaltsverzeichnis