Inhaltszusammenfassung für Kessel Aqualift F XXL 400
Seite 1
All manuals and user guides at all-guides.com ANLEITUNG FÜR EINBAU, BETRIEB UND WARTUNG Seite 1 KESSEL Hebeanlage Aqualift F XXL 400 Liter Page 25 KESSEL Hebeanlage Aqualift F XXL 800 Liter Page 49 50 Hz Baureihe Produktvorteile Sicherheit durch Schaltgerät mit...
All manuals and user guides at all-guides.com Inhalt Allgemeines ........................4 DOP/Leistungserklärung ....................4 Vorwort ..........................5 Bestimmungsgemäße Verwendung .................. 5 Gewährleistung ......................... 5 1.4.1 Ersatzteile, An- und Umbauten ..................5 1.4.2 Wartung ..........................5 1.4.3 Schäden an dem Produkt ....................5 1.4.4 Haftungsausschluss ......................
Seite 3
All manuals and user guides at all-guides.com Drehrichtung ........................15 Motorschutz ........................15 Betrieb Aqualift F XXL ....................... 15 Nach dem Einschalten ...................... 15 Instandhaltung ........................16 Allgemein .......................... 16 Wartungstermine ....................... 16 Wartungsarbeiten ......................17 Reparaturarbeiten ......................18 Allgemein .......................... 18 Wechsel von verschiedenen Pumpenteilen ..............
Sehr geehrte Kundin, sehr geehrter Kunde, wir freuen uns, dass Sie sich für ein Produkt der KESSEL AG entschieden haben. Das erworbene Produkt ist nach dem derzeitigen Stand der Technik gefertigt und geprüft. Lesen Sie sich diese Betriebsanleitung sorgfältig vor der ersten Inbetriebnahme durch.
Alarmschaltung oder sonstige geeignete Schutzmaßnahmen. Die Haftung des Herstellers schließt somit auch jegliche Haftung für Personen-, Sach- und/oder Vermögensschäden aus. 1.4.5 Herstelleradresse KESSEL AG Bahnhofstrasse 31, D-85101 Lenting, Tel.: +49 8456 / 27-0; Email: info@kessel.de, www.kessel.de 6 / 72 V 1.0...
All manuals and user guides at all-guides.com Sicherheit Sicherheit Dieses Kapitel führt alle generell gültigen Sicherheitshinweise und technische Anweisungen auf. Bei Transport, Aufstellung, Betrieb, Wartung, usw. müssen alle Hinweise und Anweisungen beachtet und eingehalten werden! Der Betreiber ist dafür verantwortlich, dass sich das gesamte Personal an die folgenden Hinweise und Anweisungen hält.
All manuals and user guides at all-guides.com Sicherheit • Werkzeuge und andere Gegenstände sind nur an dafür vorgesehenen Plätzen aufzubewahren, um eine sichere Bedienung zu gewährleisten. • Bei Arbeiten in geschlossenen Räumen muss für eine ausreichende Belüftung gesorgt werden. • Bei Schweißarbeiten und/oder Arbeiten mit elektrischen Geräten ist sicher zu stellen, dass keine Explosionsgefahr besteht.
All manuals and user guides at all-guides.com Sicherheit 2.5.2 Erdungsanschluss Unsere Anlagen müssen grundsätzlich geerdet werden. Besteht eine Möglichkeit, dass Personen mit der Anlage und dem Fördermedium in Berührung kommen, muss der geerdete Anschluss zusätzlich noch mit einer Fehlerstromschutzvorrichtung abgesichert werden. Die Elektromotoren entsprechen der Motorschutzklasse IP 68. Verhalten während des Betriebs Beim Betrieb des Produktes sind die am Einsatzort geltenden Gesetze und Vorschriften zur Arbeitsplatzsicherung, zur Unfallverhütung und zum Umgang mit elektrischen Maschinen zu beachten.
DN 100 Mindestförderhöhe 17 m Des Weiterem besitzt die Anlage das KESSEL Schaltgerät Comfort PLUS SD zur Steuerung und Überwachung aller wichtigen Funktionen. Genaueres sowie Informationen zur Inbetriebnahme des Schaltgerätes entnehmen Sie bitte der Einbau- und Bedienungsanleitung des Schaltgerätes. 10 / 72...
All manuals and user guides at all-guides.com Verpackung, Transport und Lagerung Verpackung, Transport und Lagerung Anlieferung Nach Eingang ist die Sendung sofort auf Schäden und Vollständigkeit zu überprüfen. Bei eventuellen Mängeln muss noch am Eingangstag das Transportunternehmen bzw. der Hersteller verständigt werden, da sonst keine Ansprüche mehr geltend gemacht werden können.
All manuals and user guides at all-guides.com Aufstellung und Inbetriebnahme Aufstellung und Inbetriebnahme Allgemein Um Schäden an der Hebeanlage während der Aufstellung und im Betrieb zu vermeiden sind folgende Punkte zu beachten: • Die Aufstellungsarbeiten sind von qualifiziertem Personal unter Einhaltung der Sicherheitsbestimmungen durchzuführen.
All manuals and user guides at all-guides.com Aufstellung und Inbetriebnahme • Der Zulauf wird am horizontalen Stutzen DN150 mit 700 mm bzw. 1000mm Zulaufhöhe angeschlossen. Für den gewünschten Anschluss ist jeweils die entsprechende Öffnung am jeweiligen Zulaufstutzen des Behälters abzuschneiden. Der Innendurchmesser der Zulaufleitung und der des Zulaufstutzens müssen aufeinander abgestimmt sein.
All manuals and user guides at all-guides.com Aufstellung und Inbetriebnahme Vorbereitende Arbeiten Die Maschine wurde nach dem neuesten Stand der Technik konstruiert und montiert, so dass sie unter normalen Betriebsbedingungen lange und zuverlässig arbeitet. Voraussetzung dafür ist jedoch, dass Sie alle Anforderungen und Hinweise beachten.
Störungen. Genaueres Entnehmen Sie bitte der Einbau- und Bedienungsanleitung des Schaltgerätes. Drehrichtung Bei 3Ph-Motoren muss vor der Inbetriebnahme die Drehrichtung überprüft werden. Bei Verwendung eines KESSEL Schaltgerätes wird ein Drehfeldfehler angezeigt. Bei bereits installierten Pumpen kann die Kontrolle der korrekten Drehrichtung durch den Vergleich der Förderhöhe und der Fördermenge bei unterschiedlichen Drehrichtungen...
All manuals and user guides at all-guides.com Instandhaltung Instandhaltung Allgemein Die gesamte Anlage muss in regelmäßigen Abständen überprüft und gewartet werden. Folgende Punkte sind zu beachten: • Die Betriebsanleitung muss dem Wartungspersonal vorliegen und beachtet werden. Es dürfen nur Wartungsarbeiten und –maßnahmen durchgeführt werden, die hier aufgeführt sind. •...
Die Schraube entfernen und eine geringe Menge Öl entnehmen. Wenn das Öl trübe oder milchig ist, deutet dies auf eine schadhafte Wellendichtung hin. In diesem Fall den Zustand der Wellendichtungen durch einen KESSEL- Werkskundendienst oder die KESSEL AG überprüfen lassen.
All manuals and user guides at all-guides.com Reparaturarbeiten Generell gilt beim Wechsel von Betriebsmitteln: Maschine abschalten, abkühlen lassen, vom Stromnetz trennen (vom Fachmann durchführen lassen!), reinigen und auf einem festen Untergrund in vertikaler Lage abstellen. Warme oder heiße Betriebsmittel können unter Druck stehen.
All manuals and user guides at all-guides.com Reparaturarbeiten Wechsel von verschiedenen Pumpenteilen Laufrad und Pumpengehäuse wechseln • Die Zylinderschraube mit Innensechskant am Dichtungsgehäuse lösen und abdrehen. • Das Pumpengehäuse mit geeigneten Hilfsmitteln sichern, z.B. Hilfshebevorrichtung, und vom Dichtungs- gehäuse abziehen. Auf einer sicheren Unterlage ablegen. •...
All manuals and user guides at all-guides.com Außerbetriebnahme Außerbetriebnahme Vorübergehende Außerbetriebnahme Bei dieser Art von Abschaltung bleibt die Maschine eingebaut und wird nicht vom Stromnetz getrennt. Bei einer vorübergehenden Außerbetriebnahme muss die Pumpe komplett eingetaucht bleiben, damit diese vor Frost und Eis geschützt wird.
All manuals and user guides at all-guides.com Störungssuche und -behebung Störungssuche und -behebung Um Sach- und Personenschäden bei der Beseitigung von Störungen an der Maschine zu vermeiden, sind folgende Punkte unbedingt zu beachten: • Beseitigen Sie eine Störung nur dann, wenn Sie über qualifiziertes Personal verfügen, d.h. die einzelnen Arbeiten sind von geschultem Fachpersonal durchzuführen, z.B.
Seite 22
Vorort Unterstützung durch den Kundendienst • Überprüfung bzw. Reparatur der Maschine im Werk Beachten Sie, dass Ihnen durch die Inanspruchnahme gewisser Leistungen unseres Kundendienstes, weitere Kosten entstehen können! Genaue Angaben hierzu erhalten Sie vom KESSEL Kundendienst. 22 / 72 V 1.0...
All manuals and user guides at all-guides.com Baumaße (mm) Baumaße (mm) Aqualift F XXL Duo 400L/800L Aqualift F XXL Duo 400L Aqualift F XXL Duo 800L Behälter- Mit Pumpen- Bau- typen...bis..maße Typen Aqualift F SPF 13 000 2023 XXL 400 Liter Aqualift F SPF 13 000...
All manuals and user guides at all-guides.com Führend in Entwässerung Privater Wohnungsbau ohne Kanalanbindung 1 2 3 4 1 2 3 4 Öffentlicher Bau z.B. Krankenhaus Öffentlicher Bau z.B. Freizeitanlagen 1 2 3 4 Gewerblicher Bau z.B. Hotel Gewerblicher Bau z.B.
Seite 25
All manuals and user guides at all-guides.com INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE KESSEL Lifting station Aqualift F XXL 400 litres KESSEL Lifting station Aqualift F XXL 800 litres 50 Hz series Product advantages Safety thanks to control unit with...
Seite 26
All manuals and user guides at all-guides.com Contents Contents General points ........................4 Declaration of performance ....................4 Foreword ........................... 5 Correct use ........................5 Warranty ........................... 5 1.4.1 Spare parts, additions and conversion work ..............5 1.4.2 Maintenance ........................5 1.4.3 Product damage ......................
Seite 27
All manuals and user guides at all-guides.com Contents Preparatory work ......................14 Electric system ........................14 5.5.1 Electronic control unit Aqualift Comfort Plus SD ............... 15 Direction of rotation ......................15 Motor protection ........................ 15 Operation of Aqualift F XXL ....................15 After switch-on ........................
Foreword Dear Customer, We are pleased that you have decided to buy a product from KESSEL AG. The product you have purchased has been manufactured and tested in accordance with the latest technical standards. Read these operating instructions through carefully before initial operation. This is the only way to guarantee safe and economical use of the product.
All manuals and user guides at all-guides.com Safety Safety This chapter lists all generally valid safety notes and technical instructions. All the notes and instructions must be heeded and complied with during transport, set-up, operation, maintenance etc. The operator is responsible for all members of staff keeping to the following notes and instructions.
All manuals and user guides at all-guides.com Safety • Directly following completion of the work, all safety and protective devices must be attached again or made functional again. • Accident prevention regulations as well as generally accepted technical regulations must be complied with.We would like to point out that in accordance with the Product Liability Act we are not liable for damage caused by our device if the notes and regulations in these operating instructions have not been complied with.
All manuals and user guides at all-guides.com Safety Behaviour during operation During operation of the product, the laws and regulations governing safety at the workplace, accident prevention and handling electric machinery valid at the installation location must be heeded. In the interest of a safe working procedure, the operator must delegate work to members of staff.
General description General description KESSEL Aqualift F XXL lifting stations are used for draining buildings below the backwater level as per DIN 1986. The powerful pumps and large tank volume make them particularly suitable for disposal in large private, industrial or public buildings.
All manuals and user guides at all-guides.com Packaging, transport and storage Packaging, transport and storage Delivery The shipment must be checked for damage and completeness immediately after receipt. Any shortcomings must be reported to the transport company or manufacturer on the day of receipt, since claims can no longer be made otherwise.
All manuals and user guides at all-guides.com Set-up and putting into operation Set-up and putting into operation General points To avoid damage to the lifting station during set-up and in operation, the following points must be taken into account: • Set-up work must be carried out by qualified members of staff and taking the safety regulations into account.
All manuals and user guides at all-guides.com Set-up and putting into operation • The discharge pipe should not be routed with tight elbows. The pipe must be routed above the backwater level i.e. it must be routed continually rising to above this level and then directly to the collecting pipe in a loop. •...
All manuals and user guides at all-guides.com Set-up and putting into operation Preparatory work The machine was designed and assembled in accordance with the latest technical standards so that it will work reliably for a long time under normal operating conditions. This requires you to heed all requirements and notes. Small oil leaks at the floating-ring type shaft seal following delivery are uncritical, but they must be removed before lowering or submersion into the pumping medium.
Direction of rotation The direction of rotation of 3-phase motors must be checked before initial operation. When a KESSEL control unit is used, a rotary field fault is indicated. Where pumps are already installed, the correct direction of rotation can be checked by comparing the pumping height and pumping quantity with different directions of rotation.
All manuals and user guides at all-guides.com Regular maintenance Regular maintenance General points The entire system must be checked and serviced at regular intervals. The following points must be taken into account: • The operating instructions must be available to the maintenance staff and be heeded. Only maintenance work and measures described here may be carried out.
Remove the screw and extract a small amount of oil. If the oil is cloudy or milky, the shaft seal is probably defective. In this case, have a KESSEL Factory Customer Service or KESSEL AG check the condition of the shaft seals.
All manuals and user guides at all-guides.com Repair work The following is generally valid for changing operating fluids: Switch the machine off, allow it to cool, disconnect from the mains power supply (have a specialist do this work), clean and set down vertically on a firm base. Warm or hot operating fluids can be under pressure. Escaping operating fluids can lead to burns.
Seite 43
All manuals and user guides at all-guides.com Repair work • Fix the impeller in place using suitable aids, loosen the impeller attachment (cylinder head screw with hexagon socket) and screw this out. Watch out for the screw locking device. • Pull the impeller off the shaft using a suitable removal tool.
All manuals and user guides at all-guides.com Putting out of operation Putting out of operation Putting out of operation temporarily With this type of switch-off, the machine remains installed and is not disconnected from the mains power supply. When out of operation temporarily, the pump must remain completely submersed so that it is protected from frost and ice.
All manuals and user guides at all-guides.com Troubleshooting and fault elimination Troubleshooting and fault elimination To avoid property damage and personal injury during elimination of faults on the machine, the following points must be heeded: • Only eliminate a fault if you have qualified staff i.e. the individual jobs must be carried out by trained specialists e.g.
Seite 46
• Inspection or repair of the machine at the plant Please note that costs may be incurred when certain services provided by Customer Service are used. KESSEL Customer Service can give you more detailed information about this. 46 / 72...
All manuals and user guides at all-guides.com Construction dimensions (mm) Construction dimensions (mm) Aqualift F XXL Duo 400L/800L Aqualift F XXL Duo 400L Aqualift F XXL Duo 800L Tank With pump Construction types ..to ..dimensions types Aqualift F SPF 13 000 2023 300 190...
Seite 48
All manuals and user guides at all-guides.com Leading in Drainage Private homes without public sewage connection 1 2 3 4 1 2 3 4 Public buildings (e.g. hospital) Public buildings (e.g. leisure facility) 1 2 3 4 Commercial buildings (e.g. hotel) Commercial buildings (e.g.
Seite 49
All manuals and user guides at all-guides.com 安装、运行和保养说明书 KESSEL 泵站 Aqualift F XXL 400 升 KESSEL 泵站 Aqualift F XXL 800 升 50 Hz 系列 产品优点 通过带 SDS 功能的 开关设备保证安全 (自我诊断系统) 压力传感器用于 安全获取 液位 长压力管道的有效容积大 为安全运行留出100毫米的 球状通道 设备的安装 调试 指导...
Seite 50
All manuals and user guides at all-guides.com 内容 内容 概述 .................4 DOP/性能说明 ..............4 前言 .................5 按规定使用 ..............5 保修 .................5 1.4.1 备件,加装和改装 .............5 1.4.2 保养 .................5 1.4.3 产品损坏 ..............5 1.4.4 免责条款 ..............6 1.4.5 制造商地址 ..............6 安全 .................6 说明和安全指示 ...............6 使用的指令和 CE 认证标识 .............7 一般安全提示...
Seite 51
All manuals and user guides at all-guides.com 内容 准备工作 ..............14 电气设备 ..............14 5.5.1 电子开关设备 Aqualift Comfort Plus SD ........15 旋转方向 ..............15 电机保护 ..............15 Aqualift F XXL 运行 ............15 接通后 ...............15 维护 .................16 概述 .................16 维护计划 ..............16 维护工作 ..............17 维修工作 ..............18 概述...
Seite 52
All manuals and user guides at all-guides.com 概述 概述 DOP /性能声明 52 / 72 V 1.0...
All manuals and user guides at all-guides.com 外形尺寸(mm) 外形尺寸(mm) Aqualift F XXL Duo 400 L/800L Aqualift F XXL Duo 400 L Aqualift F XXL Duo 800 L 容器- 泵的 外形尺 种..到..寸 种类 Aqualift SPF 13 000 2023 F XXL 400 升...
Seite 72
All manuals and user guides at all-guides.com Leading in Drainage Private homes without public sewage connection 1 2 3 4 1 2 3 4 Public buildings (e.g. hospital) Public buildings (e.g. leisure facility) 1 2 3 4 Commercial buildings (e.g. hotel) Commercial buildings (e.g.