g) Selecting the Protection Function
Start the programming mode as described in chapter 8. a). The yellow LED must
be lit.
As described in chapter 8 f) above, you can choose between two different pro-
tection functions:
• After input of 20 subsequent incorrect figures that do not match any saved
code, a warning sound is emitted and the code lock blocks the key pad for 30
seconds.
*53 0
Example:
• After input of 5 incorrect codes, a warning sound is emitted and the code lock
blocks the key pad for 30 seconds.
*53 1
Example:
If desired, you can programme other settings now or leave the programming
mode with the pound key (#).
33