The unit must be slid onto the inlet pipe as far as possible and
then aligned.
If a DN 100 side inlet is used, the inlet must first be opened
at the marked position using a hole saw, Ø 102, and then de-
burred. The standard inlet must then be closed using a closure
kit (accessory) and the switch-on level must be reset.
Slide the floor fixings into the side "pockets" of the tank and
then anchor them to the floor with the plugs and screws.
All other Compli. Close the sluice valve in the inlet (accessory)
to prevent any leakage of water during the installation work.
Units must be slid onto the inlet pipe, together with the clamp
flange, as far as possible and then aligned.
If a DN 150 side inlet is used, the inlet must first be opened
at the marked position using a hole saw, Ø 152, and then de-
burred. The standard inlet must then be closed using a closure
kit (accessory) and the switch-on level must be reset.
In the case of Compli 500 and 1000, the inlet can be reduced
from DN 150 to DN 100 if the enclosed reducer is first of all fit-
ted to the clamp flange.
Tighten the hexagon screws on the clamp flange.
Mark the positions of the holes for fixing the tank to the floor,
then drill the holes.
Insert the wood screw, together with the washer and wall plug,
into the drill hole in the tank and tighten it.
NOTICE! Ensure that the tank does not become deformed due to
overtightening the screws, otherwise this could result in leakage.
Installing the ventilation
Connect the ventilation pipe to the top right of the tank using the
DN 70 slip-on socket pipe and vent it above roof level.
Installing the pressure pipe
Compli 300.
NOTICE! For simplified mainte-
nance of the non-return valve
Fit the following to the non-
return valve:
1. Discharge flange
2. Flexible connector
3. Connection flange (by custo-
mer, min. 200 long)
4. Stop valve (accessory)
5. Connect the pressure pipe and
loop it over the local backup le-
vel.
Compli 400
NOTICE! When replacing a compli 400 with horizontal pressure
line, the elastic connection can be shortened.
All other Compli. Fit the following to the discharge flange:
1. Non-return valve (if not included in scope of supply)
2. Stop valve (accessory)
3. Connection flange and
4. connect the pressure pipe with the flexible connector and
loop it over the local backup level.
Additional connection, DN 50, vertical
This connection is used for emergency disposal.
Open the pipe connection at the marking using a hole saw, de-
burr the edges. and put the plug-in seal, 58/50, into place.
– Mounting Compli emergency supply connection (accessory)
– Mounting hand diaphragm pump (accessory)
Push the inlet pipe, with an external diameter of 50 mm,
into the tank through the plug-in seal. The distance from
the bottom of the tank must be at least 50 mm.
Fix the diaphragm hand pump to the wall in an easily accessi-
ble position. Connect it to the pushed-in pipe and then con-
nect the pressure pipe to the diaphragm hand pump. Here,
too, the pressure pipe must be looped over the local backup
level.
Additional inlet, DN 50, horizontal
Using a hole saw, open the additional inlet by cutting along the
pre-cut groove. Deburr the edges.
Put the plug-in seal, 58/50, into place.
Push the inlet pipe, with an external diameter of 50 mm, into
the tank through the plug-in seal.
NOTICE! The pipes that connect to the low-level inlets on the
side of the unit must be fitted with a bend, as close to the unit
as possible. The pipe invert of this bend must be at a height
of at least 180 mm above the floor on which the unit is fixed.
Air pockets in the connecting pipe can cause run-off problems
and the water could back-up. To prevent back-ups, the inlet
pipe must be vented at its highest point. The ventilation pipe
can be connected into the tank ventilation.
Installing control unit
NOTICE! Only qualified electricians may carry out electrical
works to the pump or the controls.
NOTICE! Never put the mains plug in water! If water gets into
the plug, this can cause malfunctions and damage.
Not compli 300. Only operate the control unit in dry rooms and
keep the housing closed at all times. The control unit must be
easily accessible to enable it to be checked at any time. High
humidity and condensation can destroy the controls!
Alternating current (AC) units
Only connect the pump to electrical sockets that have been
installed properly in a dry room, in accordance with the regula-
tions, and are fitted with at least a 16 A (delay) fuse.
ENGLISH
11