Activate deaeration of oil container
 Unscrew the fastening screws of the
device hood; remove the device hood.
 Cut off tip of oil container cover
 Fasten the device hood.

Attaching the Accessories

 Mount the nozzle on the spray pipe
(markings on the adjustment ring at the
top).
 Connect ray tube to hand spray gun
In devices without hose drum:
 Draw the push-handle upwards until the
stop.
 Fix the push-handle using the enclosed
screws and tool.
 Fasten the high pressure hose to the
high pressure connection.
In devices without hose drum:
 Insert the crank in the hose drum shaft
and lock it in.
 Before rolling up, stretch out the high
pressure hose.
 Wind the high pressure hose in uniform
layers on the hose drum by rotating the
crank. Select the rotation direction in
such a way that the high pressure hose
does not get bent.
Installing spare high pressure hose
 Lever out the safety clip of the hand-
spray gun using a screw-driver (Picture
A).
 Place the hand-spray gun upside down
and insert the end of the high pressure
hose till the end. Ensure that the lose
disc falls right below on the hose end
(Picture B).
 Press the safety clip back into the hand-
spray gun. The hose can be pulled out
max. 1 mm if it has been installed cor-
rectly. Otherwise, it means the disc has
been installed wrongly (picture C).
Warning
Risk of injury! Device, tubes, high pressure
hose and connections must be in faultless
condition. Otherwise, the appliance must
not be used.

Electrical connection

For connection values, see technical
data and type plate.
The electrical connections must be
done by an electrician according to IEC
60364-1.
Caution
The highest allowed net impedance at the
electrical connection point (refer to techni-
cal data) is not to be exceeded. In case of
confusion regarding the power impedance
present on your connection, please contact
your utilities provider.
Danger
Danger of injury by electric shock.
The voltage indicated on the type plate
must correspond to the voltage of the
electrical source.
The minimum fuse rating required at the
socket outlet is (see technical specifica-
tions).
The appliance should always be con-
nected to the electrical mains using a
plug. It is forbidden to permanently con-
nect the appliance to the power supply.
The plug is only for mains separation.
Check the power cord with mains plug
for damage before every use. If the
power cord is damaged, please arrange
immediately for the exchange by an au-
thorized customer service or a skilled
electrician.
The plug and coupling of the extension
cable used must be watertight.
Use the extension cord that has an ad-
equate cross-section (see "Technical
Data") and unwind it fully from the cable
drum.