Connection with inductive load
With inductive loads, the float switches should be protected by connection to
an RC element (snubber) or a free-wheeling diode.
AC voltage
Protective RC elements
Depending on the operating voltage, use RC elements exclusively in ac-
cordance with the table below. RC elements other than those specified
here will lead to the destruction of the reed switch.
RC elements for reed contacts 10 ... 40 VA
Voltage
AC 24 V
AC 48 V
AC 115 V
AC 230 V
RC elements for reed contacts 40 ... 100 VA
Voltage
AC 24 V
AC 48 V
AC 115 V
AC 230 V
Connection with conductive load
Capacitive load
14
For
RC element
see table
Resistance
100 Ω
220 Ω
470 Ω
1,500 Ω
Resistance
47 Ω
100 Ω
470 Ω
1,000 Ω
DC voltage
Capacitance
0.33 μF
0.33 μF
0.33 μF
0.33 μF
Capacitance
0.33 μF
0.33 μF
0.33 μF
0.33 μF
Electronic timers
Operating instructions, float switch, model FLS
Free wheel
ing diode
e.g.
1N4007
Type of RC el-
ement
A 3/24
A 3/48
A 3/115
A 3/230
Type of RC el-
ement
B 3/24
B 3/48
B 3/115
B 3/230