7.2.3
Replacing the burner hoses
Verify that the return line and the float chamber are completely drained
prior to replacing the burner hoses.
1. Drain the filter cup (see chapter "Replacing the filter insert").
If you release the red slider (A), it automatically returns to its base position
and the liquid fuel no longer escapes into the filter cup.
3. Replace the burner hoses.
4. Close the drain valve of the filter cup.
5. Open the shut-off valve of the suction line.
Maintenance
B
A
2. Press up the red slider (A)
using a suitable tool (for
example, screwdriver)
and hold it in this position.
- The liquid fuel is drained
from the float chamber
into the filter cup (B) and
via the drain valve
(FloCo-Top-2C only).
FloCo-Top-C