Herunterladen Inhalt Inhalt Diese Seite drucken

Function Of The Switching Outputs; Wiring - IFM Electronic efector250 Bedienungsanleitung

Kontursensor
Vorschau ausblenden Andere Handbücher für efector250:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Function of the switching outputs

After evaluation the result is available at the switching outputs of the sensor.
For the evaluation result PASS the output OUT is switched, for the result FAIL the out-
put OUT is not switched. The output READY indicates the status of the evaluation. If
it is not switched, the evaluation is still going on and the status at the output OUT is
not ready. The evaluation is only finished if the READY output is switched after the
evaluation time t
has elapsed and the result is available at the connection OUT.
E
The following diagram illustrates the correlation.
OUT ready
OUT not ready
OK
not OK

Wiring

Process connection: M12, 8-pole
Parameter setting connection: RS-422, M8, 4-pole
All manuals and user guides at all-guides.com
triggering on
positive edge
t
E
1
U+
2
trigger input
3
0V
4
trigger output for external lighting
5
switching output READY
6
switching output OUT
7
switching input IN0
8
switching input IN1
1
RxD-N/TxD-N
2
RxD-P/TxD-P
3
GND
4
RTS
trigger
input
t
E
output
READY
output
OUT
39

Werbung

Inhaltsverzeichnis
loading