Search zones and contours to be examined
search zones
On this dialogue page you can define and process up to 8 search zones. One search
zone comprises all contours or contour sections which are of interest for the evalua-
tion. Contours within one search zone are shown in yellow. When entering the dia-
logue page first an individual frame for the first search zone is automatically shown.
You can adapt the size and position of the frame by means of the mouse. All detect-
ed contours within the search zone are marked in colour.
You can generate a frame for another search zone by activating
button and then create a new frame by means of the mouse.
Please note the following:
• The search zones must not overlap.
• Search zones within other search zones are not permissible.
• A maximum of 8 search zones can be defined.
To process an existing search zone you first have to select it by double-clicking on the
frame. Then you can modify its size and position by dragging the mouse. You can
delete a selected search zone by activating the
When you have defined all required search zones, continue to the next step of para-
meter setting via the
All manuals and user guides at all-guides.com
contours within the
search zone
Next >
button.