Herunterladen Inhalt Inhalt Diese Seite drucken

Details On Energy Consumption; Wireless Remote Control - AEG DDLE ÖKO TD 18 Bedienung Und Installation

Vollelektronisch geregelter durchlauferhitzer mit temperaturfunktaster fbm comfort
Vorschau ausblenden Andere Handbücher für DDLE ÖKO TD 18:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Installation – for qualified contractors

13.3 Details on energy consumption

Product data complies with EU regulations relating to the Directive on the ecodesign of energy related products (ErP).
Manufacturer
Load profile
Energy efficiency class
Annual power consumption
Energy conversion efficiency
Default temperature setting
Sound power level
Special information on measuring efficiency

13.4 Wireless remote control

Model
Dimensions (H/W/D)
excl. wall retainer
Weight excluding wall retainer
Radio frequency
Range inside building
incl. one separating ceiling
Temperature setting range
Protection level to EN 60529
Battery type
13.5 Appliance
Electrical details
Rated voltage
Rated output
Rated current
Fuse
Phases
Frequency
Max. mains impedance at 50Hz
Specific resistance ρ
≥ (at ϑcold ≤25 °C)
15
Specific conductivity σ
≤ (at ϑcold ≤25 °C)
15
Specific resistance ρ
≥ (at ϑcold ≤45 °C)
15
Specific conductivity σ
≤ (at ϑcold ≤45 °C)
15
Connections
Water connection
Application limits
Max. permissible pressure
Max. inlet temperature for reheating
Values
Max. permissible inlet temperature
ON
Flow rate for pressure drop
Pressure drop at flow rate
DHW delivery
Δϑ at DHW delivery
Hydraulic data
Rated capacity
Versions
Connected load options
Temperature adjustment
Insulation block
Heating system heat generator
Cap and back panel
Colour
IP-Rating
38
DDLE ÖKO TD 18
222396
AEG Haustechnik
kWh
%
°C
dB(A)
None
DDLE ÖKO TD 18
222396
V
380
400
415
kW
16.2
18
19.4
A
24.7
26
27 27.6/29.5/33.3 29/31/35 30.1/32.2/36.3
A
25
25
32
3/PE
Hz 50/60 50/60
50/-
Ω 0.379 0.360 0.347
Ω cm
900
900
1000
μS/cm
1111
1111
1000
Ω cm
1200
1200
1300
μS/cm
830
830
770
G 1/2 A
MPa
1
°C
45
°C
65
l/min
>2.5
l/min
5.2
MPa
0.08
l/min
9.9
K
26
l
0.4
-
°C
30-60
Plastic
Bare wire
Plastic
white
IP25
DDLE ÖKO TD 18/21/24
222398
AEG Haustechnik
S
A
477
477
39
39
60
60
15
15
Data at Pmax. Measured with flow restric-
DDLE ÖKO TD 18/21/24 DDLE ÖKO TD 27
380
400
16.2/19/21.7 18/21/24 19.4/22.6/25.8
32/32/35 32/32/35
50/60
50/60
0.284
0.270
900
900
1111
1111
1200
1200
830
830
5.2/6.0/6.9
0.08/0.1/0.13
9.9/11.6/13.2
DDLE ÖKO TD 27
222399
AEG Haustechnik
S
S
A
A
481
39
60
15
tion on 9 Ltr/min
FBM Comfort
50/50/17 mm
30 g
868.3 MHz
25 m approx.
30 °C - 60 °C
Shower = IP X5
Bath = IP X7
CR 2032
222398
222399
415
380
400
24
27
37.1
39
32/32/40
40
40
3/PE
3/PE
50/-
50/60
50/60
0.260
0.254
0.241
1000
900
900
1000
1111
1111
1300
1200
1200
770
830
830
G 1/2 A
G 1/2 A
1
1
45
45
65
65
>2.5
>2.5
7.7
0.16
14.9
26
26
0.4
0.4
X
-
30-60
30-60
Plastic
Plastic
Bare wire
Bare wire
Plastic
Plastic
white
white
IP25
IP25

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ddle öko td 27Ddle öko td 18/21/24

Inhaltsverzeichnis