Herunterladen Inhalt Inhalt Diese Seite drucken

Assembly; Installation Location - AEG DDLE ÖKO TD 18 Bedienung Und Installation

Vollelektronisch geregelter durchlauferhitzer mit temperaturfunktaster fbm comfort
Vorschau ausblenden Andere Handbücher für DDLE ÖKO TD 18:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
ZTA 3/4 - Central thermostatic valve for
operating a DDLE ÖKO TD with preheated
water
The central thermostatic valve fitted immediately above
the cylinder ensures that the outlet temperature never
exceeds 60 °C, by admixing cold water via a bypass line.

9. Assembly

9.1

Installation location

The appliance is exclusively designed for installation on
a solid wall. Ensure the wall offers adequate load bearing
capacity. Always install the appliance vertically in a room
free from the risk of frost.
9.1.1 Appliance installation over
WW
9.1.2 Appliance installation undersink
9.2 Preparing the appliance installation
9.2.1 Opening the appliance
» Unhook the snap-in closure using a screwdriver (1).
» Flip up the appliance cover and remove it (2).
1
KW
KW
WW
2
Installation – for qualified contractors
9.2.2 Information regarding the appliance with
changeover connected load
In its delivered condition the appliance is set to 21 kW.
When changing to a different load, carry out the following
steps:
» Replug the coding card in accordance with the
selected output. Observe the corresponding
fuse protection required. For this, see chapter
"Specification".
» Mark the selected output on the type plate using a
permanent marker.
9.2.3 Anti-scalding protection
You can select the required temperature limit in the
customer service mode between 31 ... 60 °C.
9.2.4 Removing the lower section of the back panel
» Press both locking hooks inwards and pull the lower
section of the back panel forward.
1
38°
9.2.5 Securing the mounting rail
OFF
3s
» Mark out the mounting bracket fixing holes using the
55°
installation template. You can also use any suitable
mounting bracket that is already installed.
» Secure the mounting bracket with two suitable
screws and rawl plugs. The screws and rawl plugs
are not part of the standard delivery.
» Insert the threaded stud supplied into the mounting
bracket.
You can secure the appliance at the bottom with 2
additional screws. This is required if the appliance
is installed with water connections on finished walls
(installation on finished walls).
9.2.6 Fitting the power cable
≥ 30
1
2
160
2
33