Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connection; Connector S32/Cable; Connector S115 - Balluff BTL7-P511-M Serie Betriebsanleitung

Magnetostriktives positionsmesssystem — bauform stab
Vorschau ausblenden Andere Handbücher für BTL7-P511-M Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
BTL7-P511-M _ _ _ _ -BE/BF/CE/ZE/ZF-S32/S115/KA _ _ /FA _ _
Magnetostrictive Linear Position Sensor — Rod Style
4
Installation and connection (continued)
Magnet
(e.g. BTL-P-1028-15R)
Supporting rod made of non-magnetizable material
Fig. 4-9:
Example 2, BTL installed with supporting rod
4.4

Electrical connection

Depending on the model, the electrical connection is made
using a cable or a connector.
The connection or pin assignments for the respective
version can be found in Tab. 4-2 to Tab. 4-3.
Note the information on shielding and cable
routing on page 12.
4.4.1

Connector S32/cable

S32
Wire color
Pin
1
YE yellow
2
GY gray
3
PK pink
4
RD red
5
GN green
6
BU blue
7
BN brown
8
WH white
1) Unassigned leads can be connected to the GND on the controller side
but not to the shield.
Tab. 4-2:
Connection assignment BTL7...-S32
Fig. 4-10: Pin assignment of S32 (view of connector pins of BTL),
8-pin M16 circular plug
www.balluff.com
Interface
BTL7-P511...-S32/cable
+Init
+Start/stop
–Init
Not used
1)
–Start/stop
GND
10...30 V
Not used
1)
4.4.2

Connector S115

S115
Interface
Pin
BTL7-P511...-S115
1
+Init
2
+Start/stop
3
–Init
4
Not used
1)
5
–Start/stop
6
GND
7
10...30 V
8
Not used
1)
1)
Unassigned leads can be connected to the GND on the controller side
but not to the shield.
Tab. 4-3:
Connection assignment BTL7...-S115
Fig. 4-11: Pin assignment of S115 (view of connector pins of BTL),
8-pin M12 circular plug