Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connection - Balluff BIR 01 K15AL 000S92 Serie Montageanleitung

Schnelles induktives positionsmesssystem
Vorschau ausblenden Andere Handbücher für BIR 01 K15AL 000S92 Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
BIR 01- _ _ _ _ -K15AL _-000S92
Inductive Rapid Positioning System
Display elements
Balluff Standard
Signal
Meaning
Blue flashing, 3 Hz
The Device Discovery can be
activated via a system command
to find the device again.
Red flashing, 3 Hz
Short circuit at pin 2 or pin 4
Red flashing, 1 Hz
This signal occurs if a
measurement error occurs. The
measurement value is unknown
due to an error or outside of the
measuring range.
Red, static
General error
Red, static
The device is currently in teach-in
mode
Blue, static
Maintenance must be performed.
Orange flashing,
Overload on pin 2 / pin 4 has been
3 Hz
detected.
Yellow flashing,
The device is operated outside of
3 Hz
specifications. A reliable
measurement signal can no longer
be ensured.
Green, alternating
IO-Link communication is active.
with LED off in a
The device is ready.
ratio of 10:1, 1 s
period
Green, static
The device is ready
Cable routing
Defined ground!
The BIR and the control cabinet must be on the
same ground potential.
Shielding
Observe the following instructions to ensure
electromagnetic compatibility (EMC):
Connect BIR and controller using a shielded cable.
Shielding: Braided copper shield with minimum 85%
coverage.
Shield is internally connected to connector housing.
Cable routing
Do not route the cable between the BIR, controller, and
power supply near high voltage cables (inductive stray
noise is possible). The cable must be routed tension-free.
Cable length
BIR 01-_ _ _ _-K15ALA-_ _ _ _ _
BIR 01-_ _ _ _-K15ALE-_ _ _ _ _
1) Prerequisite: Construction, shielding and routing preclude the effect of
any external noise fields.
www.balluff.com
Namur Standard
Signal
Blue flashing, 3 Hz
Red flashing, 3 Hz
Red flashing, 1 Hz
Red, static
Red, static
Blue, static
Orange flashing,
3 Hz
Yellow flashing,
3 Hz
Green, alternating
with LED off in a
ratio of 10:1,
1 period
Green, static
Static white

Electrical Connection

The electrical connection is made using a connector.
Pin ...-K15ALA-... ...-K15ALE-...
1
2
3
4
5
1) Reference potential for supply voltage and EMC-GND
Max. 30 m
1)
Max. 100 m
1)
Meaning
The Device Discovery can be
activated via a system command
to find the device again.
Short circuit at pin 2 or pin 4
This signal occurs if a
measurement error occurs. The
measurement value is unknown
due to an error or outside of the
measuring range.
General error
The device is currently in teach-in
mode
Maintenance must be performed.
Overload on pin 2 / pin 4 has been
detected.
The device is operated outside of
specifications. A reliable
measurement signal can no longer
be ensured.
IO-Link communication is active.
The device is ready.
The device is ready. Diagnosis
functions are on.
The device is ready. Diagnosis
functions are switched off.
10...30 V
Output
Output
0...10 V
4...20 mA
1)
GND
C/Q (IO-Link interface)
0 V
english
3
5
4
2
1
Pin assignment
of S92 (view from
above on BIR)
3

Werbung

Inhaltsverzeichnis
loading