8. Reminder service

With the BWT reminder service, BWT's mainte-
nance information service will remind you on a
regular basis when it is time to change the filter
element and also provide important hints and tips
on hygiene. In combination with the reminder ser-
vice and the regular change of the filter element
or hygiene kit, an extended 10-year E1 guarantee
is available, depending on the national subsidiary
(see item 10).

9. Operators' obligations

According to German legislation
You have purchased a durable and service-friendly
product. However, all technical plants require regu-
lar servicing to keep them in perfect working order.
The pre-requisite for functioning and the warranty
is the replacement of the filter element and the vi-
sual inspection for leakproofness by the operator.
Verification of initial pressure every 2 months in the
case of zero flow and high levels of water removal.
A further pre-requisite for functioning and the
warranty is replacing wearing parts at the prescri-
bed maintenance intervals (see '12. Maintenance
instruction').
In accordance with DIN EN 806-5, wearing parts
must be replaced by experts (installer or factory
service centre).
We recommend entering into a maintenance con-
tract with your installer or factory service centre.
Note: Filters should not be operated by children.
Squeezing of the hand/fingers is possible.

12. Rectification of defects

Defect
Cause
Water pressure in network sharply
Filter element soiled
reduced; water pressure falls sharply
upon removal (by more than 35 % of
resting pressure)
Water pressure increases above the
Replacement or wear of
set value
sealing elements
If the defect cannot be rectified with the aid of this information, the factory service centre must be contacted..
18
Qualified staff:
The product may only be installed, commissioned
and serviced by skilled personnel. Only trained per-
sons are allowed to operate and use it.
Trained person:
Has received instruction and studied the informati-
on in this document concerning the tasks entrusted
to him/her, and the possible risks in the event of
inappropriate behaviour.
Skilled personnel:
Based on the professional training received, know-
ledge and experience, and knowledge of the rele-
vant definitions, is qualified to install the product,
to commission and to service it.

10. 10-year E1 guarantee

Depending on the BWT national subsidiary, a 10-
year guarantee is available for the new E1 filter.
The following prerequisites must be met:
- installation by a qualified expert
- proper operation
- registration (for details see www.bwt-service.com)

11. Warranty

In the event of breakdown during the warranty pe-
riod, where a maintenance contract exists please
contact our factory service centre, specifying the
type of device (see technical data or type plate
on the device). Work under warranty may only be
executed by our factory service centre. Works per-
formed under warranty by a specialist firm require
explicit commissioning by our customer service de-
partment. If no maintenance contract exists, please
contact your in-house installer.
Rectification
Replace filter element/hygienic vault
Readjust back pressure (see Com-
missioning). If the pressure increases
further the valve element (12) must be
replaced (only E1 NEU HWS)

13. Standards and legal provisions

in the most recent version in each case
The filter was manufactured in compliance with
DIN EN 13443-1 "Mechanical filters and filter combi-
nations in the drinking water installation".
The following must be heeded when installing and
operating the filter:
- DIN EN 806, Technical regulations for drinking
water installations
- DIN 1988-200, Technical regulations for drinking
water installations
- Regulation on the quality of water for human
consumption (drinking water regulation)
- Act on Regulation of the Water Household
(WHG)
- Act for promoting closed substance cycle was-
te management and ensuring environmentally
compatible waste disposal (Closed Substance
Cycle and Waste Management)
- The relevant regulations for installation, operati-
on and maintenance

14. Maintenance instructions

Drinking water is a foodstuff.
Hygienic care in the execution of works should
therefore be self-evident.
In accordance with DIN EN 806-5, maintenance
must be performed by experts (installer or factory
service centre).
Replacement of wearing parts (only original spare
parts)
Seals
every 3 yrs
Pressure reducer element (12)
every 6 yrs
Manometer (6)
every 6 yrs
Verification of initial pressure with zero flow and
high levels of water removal.
Replacement of pressure-reducing element (only
E1 NEU HWS)
Pressure reducer is located
under the cap (2). After stop-
ping the flow of water loo-
sen locking screw (10) and
turn rotary knob (11) in an
anticlockwise direction un-
til latching. Screw off spring
cover (8) with a ring wrench
(wrench width 36). Remove
pressure-reducing
element
(12) and slide ring (13).
Grease O-rings of the new
valve element with silicone
grease and insert the valve
element into the casing, hee-
ding the correct fit of the O
rings. Insert slide ring, screw
in spring cover and locking
screw. (tightening torque
35 - 40 N/m) Set pressure
reducer as described under
Commissioning. Check all
connections for leakproof-
ness (visual inspection).
Warning: Any guarantee /
warranty is void if the hygi-
ene safe is damaged, e.g.
mechanically (hygienic vault
falls on the floor) or thermal (stored under -25 °C /
over 40 °C temperature or is constantly exposed to
intense sunlight). Do not wash the filter element and
hygienic vault in the dishwasher! It must be used
only factory-new hygienic vaults, BWT replaced da-
maged parts free of charge: www.bwt-group.com.

15. Disposal

Apply to the national regulations.
- Housing and fittings made of brass
- Spring cap, valve insert and filter holder
made of plastic
- Filter element made of plastic
- Filter cup made of shock-resistant, crystalc-
lear plastic
- Elastomer seals
EN