Bender ISOMETER IR155 03-Serie Bedienungsanleitung Seite 7

Isolationsüberwachungsgerät für ungeerdete dc-antriebssysteme (it-systeme) in elektrofahrzeugen
Inhaltsverzeichnis

Werbung

Versorgung/Überwachtes IT-System
Versorgungsspannung U
...............................................DC 10 V...36 V
S
Max. Betriebsstrom I
.................................................................150 mA
S
Max. Strom I
....................................................................................2 A
k
..........................................................................6 A/2 ms Einschaltstrom
HV-Spannungsbereich (L+/L-) U
............................................................0...660 V r.m.s. (10 Hz...1 kHz)
......................................................................................DC 0 V...1000 V
Leistungsaufnahme ......................................................................< 2 W
Ansprechwerte
Ansprechwert Hysterese (DCP) .......................................................25 %
...........................................................100 kΩ...1 MΩ
Ansprechwert R
an
Unterspannungserkennung ................................................0 V...500 V
EMV
Load-Dump-Schutz (-32xx)........................................................ < 60 V*
Load-Dump Schutz (-42xx) ........................................................ < 50 V*
Messverfahren .......................................................Bender-DCP-Technik
Faktor-Mittelwertbildung F
ave
....................................................................(werksseitig eingestellt: 10)
*Bei Spannungen darüber ist ein zusätzlicher zentraler Schutz nötig.
ESD-Schutz
Kontaktentladung – direkt an den Klemmen .............................. 10 kV
Kontaktentladung – indirekt über die Umgebung .................... ≤ 25 kV
Luftentladung – Umgang mit Leiterplatte ................................. ≤ 6 kV
Anschluss
IR155-32xx
Integrierte Steckverbinder ............................TYCO-MICRO MATE-N-LOK
......................................................................................1 x 2-1445088-8
.........................................................(Kl. 31, Kl.15, E, KE, M
....................................................................... 2 x 2-1445088-2 (L+, L-);
Die Verbindung zwischen den jeweiligen Anschlusspins bei L+ bzw. L-
darf nur als Redundanz benutzt werden.
Nicht zum „Durchschleifen" geeignet!
Crimp-Kontakte ....................................TYCO-MICRO MATE-N-LOK Gold
......................................................................................14 x 1-794606-1
.........................................................Leitungsquerschnitt: AWG 20...24
Gehäuse für Crimp-Kontakte ...................................................................
................ TYCO-MICRO MATE-N-LOK receptor HSG single R -1445022-8
................ TYCO-MICRO MATE-N-LOK receptor HSG single R -1445022-2
R155-42xx
Steckverbinder ....................... Samtec Mini Mate Housing, IPD1-08-S-K
........................................................(Kl. 31B, Kl.15, E, KE, M
.................................... Molex Mini Fit Jr. Housing, 39-01-2025, (L+, L-)
Crimp-Kontakte .....................................................................................
....................... Samtec Mini Mate Gold, CC79R2024-01-L, AWG 20...24
..........................................Molex Mini Fit Jr. Gold, 39-00-0089, AWG 16
......... AC 0 V...1000 V (Spitzenwert)
n
(Ausgang M) ................................1...10
Supply/IT system being monitored
Supply voltage U
Max. operating current I
Max. current I
...........................................................................6 A/2 ms inrush current
HV voltage range (L+/L-) U
............................................................0...660 V r.m.s. (10 Hz...1 kHz)
......................................................................................DC 0 V...1000 V
Power consumption .....................................................................< 2 W
Response values
Response value hysteresis (DCP) ....................................................25 %
Response value R
Undervoltage detection ......................................................0 V...500 V
EMC
Load dump protection (-32xx) ................................................... < 60 V*
Load dump protection (-42xx) ................................................... < 50 V*
Measurement method ......................................Bender-DCP technology
Factor averaging F
*For voltages above an additional central protecion is necessary.
ESD protection
Contact discharge – directly to terminals ................................. ≤ 10 kV
Contact discharge – indirectly to environment ......................... ≤ 25 kV
Air discharge – handling of the PCB ........................................... ≤ 6 kV
Connection
IR155-32xx
On-board connectors .....................................TYCO-MICRO MATE-N-LOK
......................................................................................1 x 2-1445088-8
.........................................................(Kl. 31, Kl.15, E, KE, M
, M
, OK
)
HS
LS
HS
........................................................................ 2 x 2-1445088-2 (L+, L-)
The connection between the respective connecting pins at L+ or L-
may only be used as redundancy.
Cannot be used for looping through!
Crimp contacts ......................................TYCO-MICRO MATE-N-LOK Gold
......................................................................................14 x 1-794606-1
................................................... Conductor cross section: AWG 20...24
Enclosure for crimp contact ....................................................................s
................ TYCO-MICRO MATE-N-LOK receptor HSG single R -1445022-8
................ TYCO-MICRO MATE-N-LOK receptor HSG single R -1445022-2
R155-42xx
Connectors ............................. Samtec Mini Mate Housing, IPD1-08-S-K
........................................................(Kl. 31B, Kl.15, E, KE, M
, M
, OK
)
HS
LS
HS
.................................... Molex Mini Fit Jr. Housing, 39-01-2025, (L+, L-)
Crimp contacts ........................................................................................
....................... Samtec Mini Mate Gold, CC79R2024-01-L, AWG 20...24
..........................................Molex Mini Fit Jr. Gold, 39-00-0089, AWG 16
IR155-xx03/xx04_D00115_00_Q / 07.2021
ISOMETER® IR155-xx03/IR155-xx04
...........................................................DC 10 V...36 V
S
...........................................................150 mA
S
...................................................................................2 A
k
................... AC 0 V...1000 V (peak value)
n
.........................................................100 kΩ...1 MΩ
an
(output M) ....................... 1...10 (factory set: 10)
ave
, M
, OK
)
HS
LS
HS
, M
, OK
)
HS
LS
HS
7