Herunterladen Inhalt Inhalt Diese Seite drucken

Stopping The Machine; Emergency Stop; Normal Switch-Off; Maintenance And Servicing Plan - Zipper Maschinen ZI-RPE60C Betriebsanleitung

Vorschau ausblenden Andere Handbücher für ZI-RPE60C:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 11

Stopping the Machine

16.4.1 Emergency Stop

In case of danger and/or in an emergency situation, you can quickly switch off the machine
with the speed governor by pushing it completely into the STOP position.

16.4.2 Normal switch-off

1. Set the upper throttle lever to "minimum" and let the engine run idle for approx. 3
minutes at low engine speed.
2. Then set the engine ON/OFF switch (ignition switch) to the OFF position.
3. Close the fuel switch.
4. Wait until the engine has cooled down before storing the machine.
17
MAINTENANCE
Hot surfaces and rotating machine parts while the engine is running can cause
serious injury or even death. Always stop the machine before carrying out any
conversion, adjustment, cleaning or maintenance work and secure it against
unintentional restarting.

Maintenance and Servicing PLan

17.1.1 Table of Measures

What to do?
Check fuel level
Check engine oil level
Control of the operating elements
Check for damaged parts
Checking for loose or lost screws
Change engine oil
Check V-belt
Change exciter oil
Air filter cleaning
Spark plug test
The specified intervals refer to working under "normal" operating conditions. Depending on the
load, a change/exchange may also be necessary at an earlier point in time.

Changing the exciter oil

ZIPPER MASCHINEN GmbH
www.Zipper-Maschinen.at
ZI-RPE60C &
ZI-RPE90C33
W A R N I N G
N O T I C E
Waste oils are toxic and must not be released into the
environment! Contact your local authorities for information on proper
disposal.
Frequency
before each start-up
before each start-up
before each start-up
before each start-up
before each start-up
first after 20 h, then every 100 h
every 50 h; replacement after 300 h or 1
year
every 200 h
every 50 h, replacement after 300 h or 1
year
every 100 h; replacement after 300 h or 1
year
MAINTENANCE