SC-600-EUR Signal Clamp
Operating voltage & current
Operating frequency
Signal voltage
Output (nominal)
Operating temperature and
humidity
Storage temperature and
humidity
Operating altitude
Pollution degree
IP-rating
Drop proof
Measurement Category
Agency approval
Safety compliance
Electromagnetic Compatibility
Size (H x W x L)
Weight
TL-UAT-500 Test leads
Operating voltage and current
Leads length
Compatible transmitter
Operating temperature and humidity
Storage temperature and humidity
Operating altitude
Pollution degree
Agency approval
Safety compliance
Size (H x W x L)
Weight
0 to 600 V, 100 A max.
33 kHz (32,768 Hz) and 8 kHz (8,192 Hz)
23 V rms at 8 kHz
30 V rms at 33 kHz
-20 °C to 50 °C (-4 °F to 122 °F), ≤ 90 % RH
-40 °C to 60 °C (-40 °F to 140 °F), ≤90% RH
< 2000 m (< 6561 ft)
2
IP54
1 m (3.28 ft)
CAT IV 600 V
IEC 61010-1, IEC 61010-2-032
CSA/UL 61010-1, CSA/UL 61010-2-032
IEC 61326-1 Korea (KCC): Class A Equipment (Industrial Broadcasting &
Communication Equipment)
[1]
This product meets requirements for industrial (Class A) electromagnetic
wave equipment and the seller or user should take notice of it. This
equipment is intended for use in business environments and is not to be
used in homes.
Approx. 295 x 180 x 37 mm (11.6 x 7.1 x 1.4 in)
Approx. 0.85 kg (1.9 lb)
50 V max, 1 A
3.5 m (11.5 ft)
UAT-500-TE Transmitter
-20 °C to 50 °C (-4 °F to 122 °F), ≤ 80% RH
-40 °C to 60 °C (-40 °F to 140 °F), ≤ 80% RH
< 2000 m (< 6561 ft)
2
IEC 61010-031, CSA/UL 61010-031
Approx. 230 x 90 x 80 mm (9 x 3.5 x 3.1 in)
Approx. 0.5 kg (1.1 lb)
23