All manuals and user guides at all-guides.com
pressed. To restart operation, wait a
few seconds, then press the "Stop"
button on your remote once. Or
press the Reset button on the Central
Station.
Or short circuit. In this case, remove
the cause of the short circuit. Then
press the emergency stop button on
your MTS throttle or the Reset but-
ton on the Central Station to resume
operation. After multiple short cir-
cuits (overheating), the Central
Station will be blocked for approxi-
mately 1.5 minutes. During this time,
the Reset button is blocked as well.
- Red, constant: Central Station is
overheating. Wait until the Central
Station has cooled off. Improve air
flow to the Central Station. After the
Central Station has cooled off, the
LED flashes red. Press the emer-
gency stop button on your MTS
throttle and resume operation with
fewer locomotives.
- Red, rapid flashing (1 on, 1 off):
Error at MTS Power Extender. Short
circuit in track section connected to
the MTS Power Extender. Remove
the cause of the short circuit, etc.
(see above).
- Red, 2x asynchronous flashing (1
on, 1 off, 1 on, 5 off): MTS II Bus
overload. Check input devices for
defective wires. Remove the defec-
tive input device. Press the Reset
button on the Central Station and
resume operation.
- Red, 3x asynchronous flashing (1
on, 1 off, 1 on, 1 off, 1 on, 3 off):
MTS III Bus overloaded. Check
input devices for defective wires.
Remove the defective input device.
Press the Reset button on the
Central Station and resume opera-
tion.
- Green with pause (7 on, 1 off):
Resetpacket on tracks (tracks
remain powered, decoders switched
off; only with DiMax Navigator and
MTS III).
14
The right LED shows the incoming
LGB Bus data. It flickers irregularly.
Reset button (Fig. 2)
When you press the Reset button,
the Central Station resets. Press the
Reset button for at least one second
to activate a reset. All locos stop. All
information stored in the Central
Station (e.g., locomotive speeds) is
lost. To restart a loco, select the loco-
motive's address with a throttle. Set
the speed to 0. Then restart the loco.
Emergency Stop
To prevent accidents, each MTS
throttle features an emergency stop
button marked "STOP." When you
press this button, the Central Station
immediately switches off all power to
the layout. All locos stop. If two loco-
motives were about to collide before
you pressed the emergency stop but-
ton, set the speed of these locos to 0
during the emergency stop. (You can
send commands to the Central
Station during the emergency stop.)
After about 3 seconds, press the
emergency stop button once to
restart operation. Then all locos con-
tinue with their previous speed and
direction settings. You also can press
the Reset button during the emer-
gency stop. Then all locos are reset
to their initial setting (loco stopped,
lights, smoke off, etc.).
Programming the loco address
To operate with the Multi-Train
System, each locomotive must be
assigned a loco address. You can
program the loco address using var-
ious MTS components, for example
LGB 55016 Loco Remote (only loco
addresses 1 - 15), LGB 55015
Universal Remote and LGB 55045
MTS PC Decoder Programming
Module. Check the instructions of
these MTS components for further
information.