8.1 ONLY FOR MODEL S880SC-S900SC-S1000SC-S1200SC (TD&DD) WITH
ELECTRONIC CONTROL SYSTEM
Our models with electronic control are designed with purpose of minimizing the energy consumption, and for
that purpose they are equipped with special control systems. Your product is not only with thermostat control,
it is equipped with a control system having feature of self-learning.
It is unfavourable to mount and dismount the magnetic door switches, motion sensor and
other equipment by unauthorized people.
Control system is set so that refreshments should be kept at 3°C. This temperature value
is the plant set temperature so that you can get the optimum efficiency from the cabinet
and the ideal temperature recommended by refreshment producers.
Operating mode of electronic control system
The most important feature of the system is the self-learning module. It can sense conditions of the usage and
when the selling point that the product is placed, is open or closed and it can control the operation characteristics
in this direction. This features are provided by recording the properties as the density of the people around the
cooler, frequency of opening and closing of the door of the apparatus, light level of the environment where the
cooler is inside, with the help of the sensors.
Features that can be controlled by the control system
Control unit can open the lights of the cooler when the selling point is open and shuts off the lights when the
selling point is closed. This feature shall operate after finishing the learning period of the control system. The
light of the cooler shall be open until finishing the learning period. Please do not try to close it by yourself.
Control unit can control the inside evaporator fan. When the door is opened, inner fans are stopped. When the
equipment is in stand-by mode, inner fan operates and stops with certain intervals. Stand-by mode refers the
night or the hours that cooler is not used.
When the door of the unit is open for more than 2 minutes, control unit give signal. For this reason, it is normal
to have signal during the loading of the refreshment. When the loading is finished, signal stops with closing of
the door.
In stand-by mode control unit can lower the operation period of the compressor to the minimum levels.
Control unit applies defrost periods in certain intervals and it stops cooler system completely. After defrost
operation, system turns normal condition again.
If there is a cooling defect in your cooler, control unit gives an alarm.
Operation steps
Start your cooler in morning hours and in working hours. It is important that the energy should not shut down
during 24 hours.
Control unit shall start to learn working hours of the place it is in, and the operation characteristics of the cooler
from the first day it operates. When the control unit can identify a stabile characteristic under operating
conditions, it starts to control the cooler. This period is between 2 and 10 days.
When the learning mode is completed, control unit shall start stand-by mode after selling point is closed and
after 30 minutes it shall turn off its lights. The next day, 1.5 hours before the opening of the shop, it shall pass to
normal operating condition in order to keep the refreshments inside ready.