Herunterladen Inhalt Inhalt Diese Seite drucken

Hilti GX 90-WF Original Bedienungsanleitung Seite 27

Vorschau ausblenden Andere Handbücher für GX 90-WF:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
5.2.3
Inserting the battery
CAUTION
Risk of damage Incorrect operation of the equipment can lead to damage.
▶ Read the operating instructions for the C 7 charger for instructions on charging the battery and for further
information about use and care of the battery.
CAUTION
A falling battery presents a hazard. If the battery is not secured correctly it may drop out and fall while the
work is in progress.
▶ Check that the battery is seated securely.
WARNING
Risk of injury When inserting the battery, there is a risk of pinching the skin.
▶ Take care when inserting the battery.
1. Before inserting the battery, make sure that the battery contacts and the contacts in the tool are free of
foreign bodies.
2. From below, push the battery into the opening at the end of the grip until it snaps into place. The LED
briefly lights up in green to signal that the tool is ready for use.
3. Charge the battery fully before using the tool for the first time.
5.3
Battery state of charge
Malfunction
Green LED is on/flashes
Red LED is on/flashes
No signal
6
Operation
6.1
Settings at the nosepiece
▶ You can control the penetration depth of the nails by changing the position of the nosepiece. Use the
adjusting wheel for this purpose.
6.2
Protecting sensitive surfaces
WARNING
Risk of injury You might inadvertently trigger a misfire.
▶ Remove the battery and the gas can from the tool before installing or removing the surface protector.
*440645*
5
Possible cause
Lights
Flashes
Lights
Flashes
No LED lit up or flashing
6
7
440645
Action to be taken
▶ The battery is ready for use.
▶ Drop in battery voltage. Change
the battery soon.
▶ Battery voltage is no longer
adequate for operation of the
tool. Change the battery.
▶ Switch to the second battery, at
the latest when the LED on the
tool shows red. Recharge the
battery immediately so that it is
ready for reuse.
▶ The battery is too cold (<-15
°C / <5 °F) or too hot (>60
°C / >140 °F) and the fan
does not start. Remove the
battery and allow it to warm up
or cool down to the required
temperature.
▶ The battery voltage is below
the threshold value. Charge the
battery.
English
19

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis