Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting - Hendi 281376 Anleitung

Vorschau ausblenden Andere Handbücher für 281376:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 16
Trouble shooting
The following events can be considered as nor-
mal effects of working with this microwave.
• Radio and TV reception may be interfered
when the microwave is operating.
• The light of the oven might be dimmed when
operating.
Trouble
Microwave doesn't start
working
Oven doesn't heat
The display shows 'E-01'
or 'E-02'
The display shows 'OVEN
IS HOT DO NOT OPEN THE
DOOR'
EN
Light and fan make noise
when the microwave
finished operating.
Technical specification
Item no.: 281376
Operating voltage & frequency: 230V~ 50Hz
Rated input power: 3000W
Rated output power: 1800W
Oven cavity capacity: 18 liters
Protection class: Class I
Remark: Technical specification is subjected to change without prior notification.
14
Possible cause
Power cord not plugged in correctly.
Fuse blown of circuit breaker active.
Power outlet defective
Door not closed correctly
Temperature sensor broken
Warning is activated by the high
temperature in the chamber.
High temperatures.
• During heating steam can come from the
food and can accumulate on the cooler parts
of the microwave like for instance on the
door.
Solution
Check if the power cord is plugged in
correctly.
Replace fuse or reset circuit breaker.
If not sure how to do this contact your
supplier.
Test outlet with other appliance and
check circuit breaker.
Check the door if it closes properly,
if it can't be closed properly contact
your supplier.
Unplug the microwave from the pow-
er outlet and wait 10 seconds before
plugging the power cord back in. If
the problems isn't solved after this
contact your supplier.
Wait 3 minutes, the microwave will
cool down. Check is the vents are
clear. Never use the microwave
without food in it, don't overheat food.
If the problem isn't solved after these
steps contact your supplier.
This is normal, the lamp and fan stop
when the microwave has cooled down
enough. If they don't stop working
unplug the microwave from the power
socket and wait 10 seconds before
plugging back in. If this doesn't solve
the problem contact your supplier.
Microwave frequency: 2450MHz
Dimension: 420x563x(H)340 mm
Net weight: approximately 31,6 kg
USB card operation system requirements:
Windows 2000/XP/2003/Vista or above