11.16 Gerätestatus-Codes
Die Gerätestatus-Codes sind nur für Service-Arbeiten gedacht. Sie sollten nicht für
Standardvorgänge verwendet werden.
Diagnose
Kurztext
Code
F101
NXA 820 Conn. Lost Unable to Communicate with NXA820
F301
Data Mem. Fault
F302
LAN Fault
F303
SYNC Fault
F304
FPGA Error
F305
NV Data Error
F306
Order Code Error
F308
Watchdog Error
F309
FS Security Err
F310
High CPU Load
F311
Low Disk Space
F312
Low RAM
F313
Bad Thread
F314
Reset by WD
F315
CheckSum Error
F316
Language Error
F317
Access Cnfg Err
F318
FPGA Config Err
F319
RTC LowVolt Err
F320
Time Read Err
F321
Time maybe bad!
F322
RTC Nvmgr Err
F501
Database Fault
F502
Not Configured
C503
HART Tunneling
F504
Subscrip. Store
M505
Time Server
C506
Field Scan Off
C507
Interface Off
C508
SYSTOOL Error
Grund
Failed to Detect or Initialize Data Flash Memory
LAN Cable Disconnected or Failed
SYNC Link Cable Disconnected or Failed
Unable to access FPGA
The data in the NV memory does not match the
RAM copy
The factory set order code is invalid, NXA is
unable to startup
Software Watchdog Error
Security policy compromised due to file-system
error
High CPU Utilization
Low Disk Space
Low RAM
Bad Thread Status
Hardware reset by WatchDog
CheckSum Error
Language Installation Error
Access Configuration Error: No machines regis-
tered for access
fpga.conf file is corrupted or not available
Real Time Clock Battery Low voltage Detected
Real Time Clock Read Error
Time maintained by the RTC might be wrong
RTC could not access NV memory to store or
retrive time
Database Failure
LAN Has Not Been Configured
Gauge Configuration In Progress
Subscription Store Cannot Be Found
The fieldscan has been stopped
The hostlink interface has been stopped
SYSTOOL execution error
Menü "System"
Mögliche Lösung
To reprogram with proper SREC
The battery might have drained if
the kit was off for a long duration
Check if i2cdriver started and
working fine
Confirm and set the time on the
kit
Check if nvmanager started and
working fine
183